![](/images/new-backgrounds/1279183/27918373x1.webp)
PDxx01 | Page: 37 / 49 |
Document Version [1.0]
5-54. S1/S2 SELECT
Function
External control apparatus sets up the S1/S2 detection of a plasma monitor.
Transmission Data
DFH 80H 60H 89H 01H DATA00 CKS
| DATA00 | 01H: AUTO |
|
| 02H: OFF |
ACK |
| |
|
| |
| 7FH 60H 80H 89H 01H DATA00 CKS | |
| DATA00 | 01H: AUTO |
|
| 02H: OFF |
5-55. SOFT FOCUS
Function
External control apparatus sets up the Soft Focus of a plasma monitor.
Transmission Data
DFH 80H 60H 65H 01H DATA00 CKS
DATA00 01H: OFF 02H: LEVEL1
03H: LEVEL2
04H: LEVEL3
05H: LEVEL4
ACK
7FH 60H 80H 65H 01H DATA00 CKS
DATA00 01H: OFF 02H: LEVEL1
03H: LEVEL2
04H: LEVEL3
05H: LEVEL4
5-56. BLACK LEVEL SELECT
Function
External control apparatus sets up the black level (digital signal level) of a plasma monitor.
Transmission Data
DFH 80H 60H 8FH 01H DATA00 CKS
DATA00 01H: LOW 02H: HIGH
ACK
7FH 60H 80H 8FH 01H DATA00 CKS
DATA00 01H: LOW 02H: HIGH
Company Restricted