Marantz PDxx01 specifications Power on, Power OFF, Input Switch Change

Page 8

PDxx01

RS-232C Control Specification

Page: 8 / 49

Document Version [1.0]

5. Command

5-1.Power ON

Function

The external control equipment switches on the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4EH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched on.

3FH 60H 80H 4EH 00H CKS

NOTE: Do not set the Power ON or Power OFF command continuously.

5-2.Power OFF

Function

The external control equipment switches off the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4FH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched off.

3FH 60H 80H 4FH 00H CKS

NOTE: Do not set the Power ON or Power OFF command continuously.

5-3.Input Switch Change

Function

The external control equipment switches the input of the plasma monitor.

Transmission Data

DFH 80H 60H 47H 01H DATA00 CKS

DATA00 : Input Select

01H

: Video1

 

02H

: Video2

 

 

05H : DVD/HD1

 

06H

: DVD/HD2

 

07H

: PC/RGB

0EH : DVD/HD3(HDMI)

1AH : DVD/HD4(HDMI)

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 47H 00H CKS

Company Restricted

Image 8
Contents PDxx01 RS-232C Control Specification Table of Contents Revision history Connections should be made as described below WiringCommunication Parameters Command1 CommandCheck Sum CKS, Error Processing, and ACK Unit ID1,2 UA1,UA2Command Reference List Picture Freeze DFH 7CH Input Switch Change Power onPower OFF Audio Mute OFF Volume Gain DataAudio Mute on Contrast Gain Data Bright Gain DataSharpness Gain Data Color Gain DataPicture Mode Select Tint Gain DataDFH 80H 60H 0AH 01H DATA00 CKS 7FH 60H 80H 0AH 01H DATA00 CKSColor Temp Select RED Gain DataDFH 80H 60H 00H 01H DATA00 CKS 7FH 60H 80H 00H 01H DATA00 CKSGreen Gain Data Blue Gain DataNR Mode Set Bass Gain DataDFH 80H 60H C0H 01H DATA00 CKS 7FH 60H 80H C0H 01H DATA00 CKSTreble Gain Data Balance Gain DataScreen Mode Select 22.V. Position Gain DataDFH 80H 60H 51H 01H DATA00 CKS 7FH 60H 80H 51H 01H DATA00 CKS25.H. Width Gain Data 23.H. Position Gain Data24.V. Height Gain Data 7FH 60H 80H 7FH 03H DATA00 DATA01 DATA02 CKS Phase Fine Picture Gain DataAuto Picture Select Clock Picture Adjust Gain Data Power MGT SelectOSM ADJ. Position Data 7FH 60H 80H 1AH 01H DATA00 CKSLong Life Set PDP Saver Set Cinema Mode SetGray Level Set ALL Reset Screen Wiper SetAudio Select Set DFH 80H 60H 70H 02H DATA00 DATA01 CKS7FH 60H 80H 8BH 01H DATA00 CKS RGB SelectDFH 80H 60H 8BH 01H DATA00 CKS Vmode:7 @70 @72 Mode:10 1024×768 1152×864 Mode:8 @75 HD Select Language SelectFrequency Request Signal Information Color System Select01H to 80H RGB signal 81H58NTSC 82H 43NTSC 83H 84HInput Mode Request Video ADJ. RequestPDxx01 RS-232C Control Specification Document Version 7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS Audio Select Request1FH 80H 60H 6FH 00H CKS 7FH 60H 80H 3FH 02H DATA00 DATA01 CKS Failure Mode Request1FH 80H 60H 3FH 00H CKS 7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS Model Name Request1FH 80H 60H 17H 00H CKS LOW Tone 50inch only Color TuneDFH 80H 60H 0CH 01H DATA00 CKS 7FH 60H 80H 0CH 01H DATA00 CKSGamma Gain Data Running SenseSerial No. Request OSM OrbiterInput Skip Black Level Select 54.S1/S2 SelectSoft Focus Multi Sprit Screen Select DFH 80H 60H 07H 01H DATA00 CKSSUB Picture Detect Select 7FH 60H 80H 07H 01H DATA00 CKSDFH 80H 60H 7AH 01H DATA00 CKS 7FH 60H 80H 7AH 01H DATA00 CKSZoom Navigation Select Picture Freeze SelectDFH 80H 60H 7BH 01H DATA00 CKS DFH 80H 60H 7CH 01H DATA00 CKSCC Closed caption Select Picture Freeze Pause CommandOSM Contrast Select CC Closed caption Contrast Select Picture Memory SelectDFH 80H 60H 25H 02H DATA00 DATA01 CKS Picture Memory SetPicture Memory Note Write Set SET UP Level Select Back Ground SelectAudio Hdmi Request Power on Mode InputPDP Saver Auto Select Power on Mode Volume SUB Picture Rate setDFH 80H 60H 0FH 01H DATA00 CKS 7FH 60H 80H 0FH 00H CKS7FH 0H 80H 33H 00H CKS Multi Sprit Screen Power on Mode SETDFH 80H 60H 33H 04H DATA00 to DATA03 CKS Under Scan Setting Remote Code SettingVolume Gain Data Request Revision history