PDxx01 | Page: 19 / 49 |
Document Version [1.0]
5-26. AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
| DATA00: USER PICTURE Gain Flag | 03H | |
| DATA01: AUTO PICTURE Select Flag | 09H | |
| DATA02 | 00H: ON |
|
|
| 01H: OFF |
|
ACK |
|
| |
|
| ||
| 7FH 60H 80H 7FH 03H DATA00 DATA01 DATA02 CKS | ||
| DATA00: USER PICTURE Gain Flag | 03H | |
| DATA01: AUTO PICTURE Select Flag | 09H | |
| DATA02 | 00H: ON |
|
|
| 01H: OFF |
|
5-27. PHASE (FINE PICTURE) Gain Data
Function
The external control equipment changes the PHASE gain data (Phase) of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
| DATA00: USER PICTURE Gain Flag | 03H |
| DATA01: PHASE Gain Flag | 03H |
| DATA02: PHASE Gain | 00H: 0 |
|
| : |
|
| 40H: +64 : |
ACK |
| |
| 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS | |
| DATA00: USER PICTURE Gain Flag | 03H |
| DATA01: PHASE Gain Flag | 03H |
Company Restricted