![](/images/new-backgrounds/1279183/27918369x1.webp)
PDxx01 | Page: 35 / 49 | |
|
| Document Version [1.0] |
|
|
|
DATA06: RESET | 00H: OFF |
|
| 01H: ON |
|
ACK
7FH 60H 80H 0DH 00H CKS
5-49. GAMMA GAIN Data
Function
External control apparatus changes Gamma of a plasma monitor.
Transmission Data
DFH 80H 60H 13H 02H DATA00 DATA01 CKS
DATA00: GAMMA FLAG | 01H: Gamma change |
DATA01: GAMMA | 00H: 1(GAMMA2.1) |
| 01H: 2(GAMMA2.2) |
| 02H: 3(GAMMA2.3) |
| 03H: 4(GAMMA2.4) |
ACK
7FH 60H 80H 13H 01H DATA00 CKS
DATA00: GAMMA FLAG 01H: Gamma change
5-50. Running Sense
Function
External control apparatus grasps the power supply state of a plasma monitor.
A plasma monitor is made to recognize connection of PC CONTROL.
Transmission Data
1FH 80H 60H 88H 00H CKS
ACK
7FH 60H 80H 88H 01H DATA CKS
DATA: Bit0: Connect Condition
0:No connection
1:Connected
Bit1 0: Fixed 1:-
Bit2: Power Status
0:POWER ON
1:POWER OFF (STANBY) Bit3 0: Fixed
Bit4 0: Fixed
Bit5 0: Fixed
Bit6 0: Fixed
Bit7 0: Fixed