KTI Networks KSC-240 manual Factory Default Configuration, Name Default Setting

Page 43

5 Factory Default Configuration

The following table lists the factory default settings for configuration

DIP SW:

SW

Name

Default Setting

SW1-2&1

4W

4-wire (RS-485/422 driver receiver separated)

SW1-3

T-D(Off)

Disable RS-485/422 receiver terminator

SW1-4 TXC (Off)

RS-485/422 driver enable control by RTS orADC

SW1-5

RTS-D (Off)

Disable RTS control for RS-485/422 driver

SW1-6 RXC (Off)

RS-485/422 receiver enable control by RTS orADC

SW1-8&7 BIAS-D (Off)

Disable RS-485/422 line bias

SW2-1

SDE (On)

EnableADC control for RS-485/422 driver

SW2-2

Off

Disable ADC Timing for RS-232 baud 1200

SW2-3

Off

Disable ADC Timing for RS-232 baud 2400

SW2-4

Off

Disable ADC Timing for RS-232 baud 4800

SW2-5

9600 (On)

Select ADC Timing for RS-232 baud 9600

SW2-6

Off

Disable ADC Timing for RS-232 baud 19200

SW2-7

Off

Disable ADC Timing for RS-232 baud 38400

SW2-8

Off

DisableADC Timing for RS-232 baud 115200

-43-

Image 43
Contents Industrial RS-232 to RS-485/422 Converter KSC-240 Installation GuideInternational United StatesEthernet is a registered trademark of Xerox Corp Table of Contents Introduction Features Specifications Serial Interface RS-232 Port LEDIndicatorsRS-485/422 Interface Name State Function Configuration DIP SW SettingsEnvironmental DC Power InterfaceBasic Information MechanicalCE/EMC CertificateUnpacking InstallationSafety Cautions DIN-Rail Mounting Page Panel Mounting Screw locations and final dimension are shown below Using Terminal Blocks Applying PowerPage UsingDC Power Jack Power Failure Relay Output SW1-2 DIP SW ConfigurationSW1-3 TXE SW1-4SW1-6 SW1-5SW1-8&7 SW2-4 SW2-1SW2-2 SW2-3SW1-4 SW1-6 SW1-5 SW2-1 Behavior 1 RS-485/422 Driver and Receiver ControlTypical RS-232 Interface DCE Pin Assignment Table Making Serial RS-232 ConnectionSignal Name Input/Output Cable for Connection to PC COM Port Making RS-485/422 Connection Characteristics RS-422 RS-485RS-422 Point-to-Point Circuit RS-422 Multi-drop Network TXE RS-485 Multi-drop Network TXC RS-485 Half-duplex 2-wire Network RS-485 Full-duplex 4-wire Network Or use ADC control optional Summary of the Converter Applications LED Indicators Name Default Setting Factory Default Configuration