KTI Networks KSC-240 manual Configuration DIP SW Settings, Name State Function

Page 9

Configuration DIP SW Settings

SW

Name

State

Function

SW1-2&1

4W

Off

4-wire (RS-485/422 driver receiver separated)

 

2W

On

2-wire (RS-485/422 driver receiver connected)

SW1-3

T -D

Off

Disable RS-485/422 receiver terminator

 

T -E

On

Enable RS-485/422 receiver terminator

SW1-4

TXC

Off

RS-485/422 driver enable control by RTS or ADC

 

TXE

On

RS-485/422 driver is forced to enable

SW1-5

RTS-D

Off

Disable RTS control for RS-485/422 TX RX

 

RTS-E

On

Enable RTS control for RS-485/422 TX RX

SW1-6

RXC

Off

RS-485/422 receiver enable control by RTS or ADC

 

RXE

On

RS-485/422 receiver is forced to enable.

SW1-8&7

BIAS-D Off

RS-485/422 line bias is disabled

 

BIAS-E On

RS-485/422 line bias is enabled

SW2-1

SDD

Off

Disable ADC control for RS-485/422 TX RX

 

SDE

On

Enable ADC control for RS-485/422 TX RX

SW2-2

1200

On

ADC Timing parameter for RS-232 baud 1200

SW2-3

2400

On

ADC Timing parameter for RS-232 baud 2400

SW2-4

4800

On

ADC Timing parameter for RS-232 baud 4800

SW2-5

9600

On

ADC Timing parameter for RS-232 baud 9600

SW2-6

19200

On

ADC Timing parameter for RS-232 baud 19200

SW2-7

38400

On

ADC Timing parameter for RS-232 baud 38400

SW2-8

115200 On

ADC Timing parameter for RS-232 baud 115200

-9-

Image 9
Contents Industrial RS-232 to RS-485/422 Converter KSC-240 Installation GuideInternational United StatesEthernet is a registered trademark of Xerox Corp Table of Contents Introduction Features Specifications LEDIndicators Serial Interface RS-232 PortRS-485/422 Interface Name State Function Configuration DIP SW SettingsBasic Information DC Power InterfaceMechanical EnvironmentalCE/EMC CertificateUnpacking InstallationSafety Cautions DIN-Rail Mounting Page Panel Mounting Screw locations and final dimension are shown below Using Terminal Blocks Applying PowerPage UsingDC Power Jack Power Failure Relay Output SW1-2 DIP SW ConfigurationSW1-3 TXE SW1-4SW1-6 SW1-5SW1-8&7 SW2-2 SW2-1SW2-3 SW2-4SW1-4 SW1-6 SW1-5 SW2-1 Behavior 1 RS-485/422 Driver and Receiver ControlTypical RS-232 Interface DCE Pin Assignment Table Making Serial RS-232 ConnectionSignal Name Input/Output Cable for Connection to PC COM Port Making RS-485/422 Connection Characteristics RS-422 RS-485RS-422 Point-to-Point Circuit RS-422 Multi-drop Network TXE RS-485 Multi-drop Network TXC RS-485 Half-duplex 2-wire Network RS-485 Full-duplex 4-wire Network Or use ADC control optional Summary of the Converter Applications LED Indicators Name Default Setting Factory Default Configuration