KTI Networks KSC-240 manual Serial Interface RS-232 Port, RS-485/422 Interface, LEDIndicators

Page 8

Serial Interface (RS-232 Port)

 

Connector

 

DB9 female

 

Pin Assignments

DCE type

 

Baud Rate Support

Up to 115K baud

 

Connector Shield

Connect to chassis ground

Connection Distance

15 meters

 

High ESD Tolerance

+/-15KV on Tx, Rx lines

Overvoltage Protection

Cutoff if over +/-28V

 

Isolation

 

Optical isolation with RS-485/422 interface

RS-485/422 Interface

 

 

Connector

 

Screw-type terminal block

Signal Type

Balanced differential lines

Data Speed

115Kbps

 

Standard

 

EIA-485, EIA-422

 

High ESD Tolerance

+/-15KV on driver and receiver lines

Overvoltage Protection

Cutoff if over +/-28V

 

LEDIndicators

 

 

LED

DISPLAY

STATE

INTERPRETATION

PWR

Power status

ON

Power on

 

 

OFF

Power off

232 TX RS-232 TX

BLINK

RS-232 TXActivity

232RX RS-232RX

BLINK

RS-232 RXActivity

TXC

RS-485/422 TX control ON

RS-485 driver is enabled

 

 

OFF

RS-485 driver is disabled

-8-

Image 8
Contents KSC-240 Installation Guide Industrial RS-232 to RS-485/422 ConverterUnited States InternationalEthernet is a registered trademark of Xerox Corp Table of Contents Introduction Features Specifications RS-485/422 Interface LEDIndicatorsSerial Interface RS-232 Port Configuration DIP SW Settings Name State FunctionDC Power Interface Basic InformationMechanical EnvironmentalCertificate CE/EMCInstallation UnpackingSafety Cautions DIN-Rail Mounting Page Panel Mounting Screw locations and final dimension are shown below Applying Power Using Terminal BlocksPage UsingDC Power Jack Power Failure Relay Output DIP SW Configuration SW1-2SW1-3 SW1-4 TXESW1-5 SW1-6SW1-8&7 SW2-1 SW2-2SW2-3 SW2-41 RS-485/422 Driver and Receiver Control SW1-4 SW1-6 SW1-5 SW2-1 BehaviorMaking Serial RS-232 Connection Typical RS-232 Interface DCE Pin Assignment TableSignal Name Input/Output Cable for Connection to PC COM Port Characteristics RS-422 RS-485 Making RS-485/422 ConnectionRS-422 Point-to-Point Circuit RS-422 Multi-drop Network TXE RS-485 Multi-drop Network TXC RS-485 Half-duplex 2-wire Network RS-485 Full-duplex 4-wire Network Or use ADC control optional Summary of the Converter Applications LED Indicators Factory Default Configuration Name Default Setting