Panasonic WJ-FS316, WJ-FS409 Monitor Output Setup Menu, MLT OUT Mode, SPT OUT Mode, Multi Output

Page 13

9. MLT OUT MODE

This item lets you select whether to switch the multiscreen output monitor screen automatically to the camera picture of the channel whose alarm is activated.

1.Move the cursor to the MLT OUT MODE parameter.

2.Select OFF or SPOT by pressing the + or button. The initial factory setting is SPOT.

OFF: Ignores alarm activation and continues to display the pictures in the mode selected previously. All buttons except alarm reset button do not valid on condition that alarm reset does not complete.

SPOT: The camera picture whose alarm is activated is displayed and retained until the alarm is reset.

10. SPT OUT MODE

This item lets you select whether to switch the spot output monitor screen automatically to the camera picture of the channel whose alarm is activated.

1.Move the cursor to the SPT OUT MODE parameter.

2.Select OFF or SPOT by pressing the + or button. The initial factory setting is SPOT.

OFF: Ignores alarm activation after and continues to display the pictures in the mode selected previous- ly. All buttons except alarm reset button do not valid on condition that alarm reset does not complete.

SPOT: The camera picture whose alarm is activated is displayed and retained until the alarm is reset.

Monitor Output Setup Menu

1. MULTI OUTPUT

WJ-FS316 SETUP

ALARM SETUP

MONITOR OUTPUT SETUP

REC OUTPUT SETUP

SEQUENCE SETUP

SYSTEM SETUP

Move the cursor to MONITOR OUTPUT SETUP on the SETUP menu, then press the SET button. The MONI- TOR OUTPUT SETUP menu appears on the monitor screen as shown below.

MONITOR OUTPUT SETUP

MULTI OUTPUT

 

TITLE DISP

ON

STILL DISP

ON

BORDER

WHITE

QUAD SHIFT

OFF

SECRET VIEW

OFF

SPOT OUTPUT

 

TITLE DISP

ON

1-1. TITLE DISP

This item lets you enable or disable the camera title display overlaid on the multiscreen picture.

1.Move the cursor to the TITLE DISP parameter.

2.Select ON or OFF by pressing the + or button. The initial factory setting is ON.

ON: Enables display of the camera title.

OFF: Disables display of the camera title.

1-2. STILL DISP

This item lets you enable or disable the subtitle “STILL” overlaid on the multiscreen output picture.

1.Move the cursor to the STILL DISP parameter.

2.Select ON or OFF by pressing the + or button. The initial factory setting is ON.

ON: Enables display of the subtitle “STILL”.

OFF: Disables display of the subtitle “STILL”.

13

Image 13
Contents WJ-FS316 WJ-FS409 WJ-FS416 Lightning flash with arrowhead sym Contents Preface FeaturesSegment Screen Do not drop metallic parts through slots PrecautionsDo not attempt to disassemble the appliance Handle the appliance with careAlarm Reset Button Alarm Reset Power Switch Power ON/OFFAlarm Indicator Alarm WJ-FS316/FS416Sequence Button SEQ Spot/Multiscreen Selection ButtonIncrement/Decrement Buttons -, + 0Set Button SETRear View Displaying the Setup Menu Setup MenuSetup Menu ALM REC Mode Alarm Setup MenuDynamic REC ALM Display Auto ResetALM Output ALM BuzzerMLT OUT Mode Monitor Output Setup MenuSPT OUT Mode Multi OutputSpot OUT Record Output Setup MenuTitle Display REC Mode Sequence Setup MenuAuto Skip Step Assignment SEQ ModeMLT/SPT SEQ Setup System Setup MenuTitle Setup Spot OutputCAM SW Loss Title PosiPlayback Auto To erase a specific characterPWR on Multi PasswordPWR on Spot ON→Communication Setup SW Interval EncodeMounting in the Rack InstallationsBasic System Connection System ConnectionsVideo Multiplexer WJ-FS309/FS409 Connect the time lapse VCR as shown in the example below Connection with the Time Lapse VCRALARM/REMOTEDATA Camera GND Multi Connection with the WV-CU360 System Controller Connection with the MonitorsSpot ALARM/REMOTE ConnectorConnection with the Alarm Output Connection with the Alarm SensorsNC no Remote SW1 Connection with the Remote External SwitchesMonitoring the Camera Picture Operating ProceduresSpot Multiscreen SEQVCR CAM Multiscreen OUTStill Spot Picture Still Multiscreen Picture Multiscreen PictureMultiscreen Sequence Monitoring the Playback Picture Recording on the Time LapseSpot Playback Picture Still Spot Playback Picture Zoomed Spot Playback PictureStill Multiscreen Playback Picture Multiscreen Playback PicturePlayback Multiscreen Sequence Alarm Input Alarm Control FunctionAlarm Operation Manual Reset Alarm ResetAuto Reset External ResetCamera Switching Pulse Loss Display ALL ResetChannel Loss Alarm Other FunctionsData Format AppendixAscii Video Multiplexer to System ControllerAll camera channels in a multiscreen Standard Accessories SpecificationsPanasonic Canada Inc

WJ-FS409, WJ-FS316, WJ-FS416, WJ-FS309 specifications

Panasonic's WJ-FS309, WJ-FS416, WJ-FS316, and WJ-FS409 are robust digital video multiplexers designed to enhance surveillance systems. These models incorporate advanced technologies and features critical for effective video management, making them suitable for various applications, including retail security, transportation, and public safety.

The WJ-FS309 is known for its versatile functionality, allowing users to view and manage multiple camera feeds on a single display. It supports up to nine inputs, offering a compact solution for smaller installations. Its user-friendly interface simplifies operation, while features like real-time monitoring and on-screen display options enhance usability.

WJ-FS316 is an upgraded version, capable of accommodating 16 camera inputs. This model is equipped with a high-performance processor that ensures smooth video playback and rapid switching between feeds. It also features built-in motion detection, which alerts users to unusual activity, thereby increasing security effectiveness. Additionally, the WJ-FS316 supports a variety of output resolutions, providing flexibility for different display setups.

The WJ-FS409 stands out with its support for 4CIF resolution, ensuring high-quality video output essential for detailed surveillance. It also includes advanced video analysis capabilities, such as video motion detection and mask programming, which allow users to filter out unnecessary information, thus focusing on critical events. This feature is particularly useful in locations with high foot traffic, as it helps reduce the workload for security personnel.

The WJ-FS416 is a comprehensive solution that combines features from both the WJ-FS309 and WJ-FS409. It supports 16 channels and offers high-quality image processing, making it ideal for extensive surveillance systems. Its flexibility extends to network integration, allowing for seamless connectivity with existing security infrastructure. Users can remotely access camera feeds, creating a more dynamic monitoring experience.

Overall, these Panasonic models provide a robust and scalable approach to video surveillance. They incorporate essential technologies that streamline video management while ensuring high image quality and effective security monitoring. Through their thoughtful design and advanced features, the WJ-FS series underscores Panasonic's commitment to delivering reliable and innovative solutions for modern surveillance challenges.