Panasonic WJ-FS316, WJ-FS409, WJ-FS309, WJ-FS416 manual All camera channels in a multiscreen

Page 41

Item

Format

 

 

Example

 

 

 

 

 

 

 

 

 

Note/Parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Still

OST : ccccc : m

OST : 00005 : 1

 

 

 

 

“cccc” expresses individual camera channel or

 

 

CH #5 will be stilled.

 

 

all camera channels in a multiscreen.

 

 

 

OST : ccccc : m

 

 

 

 

ccccc = 00001 to 00128 For individual

 

 

Every segment in a

 

 

 

ccccc = 00000

For all in a multiscreen

 

 

multiscreen will be stilled.

 

“m” denotes display mode selection.

 

 

 

 

 

 

 

 

 

 

m = 0: STILL OFF

 

 

 

 

 

 

 

 

 

 

 

 

m = 1: STILL ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multiscreen Pattern Select

OTC : +

OTC : +

 

 

 

 

 

4-segment, 9-segment or 16-segment toggles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setup

MSU : n

MSU : 1

 

 

 

 

 

m = 0 : End Setup

 

 

 

 

 

 

 

 

 

 

 

 

m = 1 : Begin Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cursor Movement and

DCR : nn

DCR : G1

 

 

 

 

 

“nn” denotes as follows.

 

Parameter Select

 

Down the cursor in SETUP

 

nn = A1 Move the cursor to Right

 

 

DCR : A1

 

 

 

 

 

nn = C1 Move the cursor Upward

 

 

Move the + sign to right

 

 

nn = E1

 

 

Move the cursor to Left

 

 

 

for Zooming

 

 

 

 

nn = G1

 

 

Move the cursor Downward

 

 

 

 

 

 

 

 

 

nn = +1

 

 

Select parameter (+)

 

 

 

 

 

 

 

 

 

 

nn = –1

 

 

Select parameter (–)

 

 

 

 

 

 

 

 

 

 

nn = PD

 

 

(Divide into the submenu by SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

button.)

 

 

 

 

 

 

 

 

 

 

 

 

nn = PU

 

 

(Return to upper menu by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU/ESC button.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Recovery

OAL : n

OAL : 0

 

 

 

 

 

“n” denotes ALARM indicator status after recov-

 

 

 

 

 

 

 

 

 

ery as follows.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

nn = 0 Turns OFF

 

 

 

 

 

 

 

 

 

 

 

 

nn = 1 Turns ON

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Input

DAI: b1b2b3a1a2a3a4

(Send 1) 5 channel: Alarm mode

 

Bit Position

 

 

 

 

 

 

[sfx]ADOOA; ALM:[OF][OF][OF]

 

7 6 5 4 3 2 1 0

 

 

b1b2b3=Notice of

 

[OF][B7][OF][efx]

 

 

 

P P P P O O O O

 

 

First Alarm Channel

(Response) None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a1a2a3a4=Notice of

5ch: Alarm mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Channel

b1

b2

b3

a1

a2

a3

a4

 

 

 

 

 

 

 

Checking Code

 

 

 

0Fh 0Fh 0Fh 0Fh 87h 0Fh 0Fh

 

 

 

 

 

 

 

Data that bit reversed notice

 

 

5ch, 15ch, 16ch: Alarm mode

 

 

 

 

 

 

 

 

 

 

 

bn

 

 

 

 

 

 

of First Alarm Channel

 

 

b1

b2

b3

a1

a2

a3

a4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3-digit number)

 

 

 

0Fh 0Fh 0Fh 0Fh 87h 0Fh 3ch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17ch: Alarm mode

 

 

 

 

Notice of First Alarm Channel

 

 

 

b1

b2

b3

a1

a2

a3

a4

 

 

 

 

0Fh 0Fh 1Eh 87h 0Fh 0Fh 0Fh

 

(3-digit number)

 

 

 

 

 

128ch: Alarm mode

 

 

 

 

Value: 0 - F

 

 

 

 

 

 

b1

b2

b3

a1

a2

a3

a4

 

(Example 1) bn = 0001 1110

Value: 1

 

 

0Fh 0Fh 78h 0Fh 0Fh 0Fh 1Eh

 

 

 

 

 

 

 

 

 

 

 

(Example 2) bn = 0011 1100

Value: 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

5

4

3

2

1 0

 

 

 

 

 

 

 

 

 

 

 

P P P P O O O O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Checking Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data that bit reversed notice

 

 

 

 

 

 

 

 

 

an

 

 

 

 

 

 

of First Alarm Channel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3-digit number)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notice of First Alarm Channel

 

 

 

 

 

 

 

 

 

 

 

(3-digit number)

 

 

 

 

 

 

 

 

 

 

 

Value: 0 - F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Example 1) an = 0001 1110

Value: 1

 

 

 

 

 

 

 

 

 

 

(Example 2) an = 0011 1100

Value: 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Take a break for at least 270 ms (equivalent to 16 V Sync) from one transmission to the next especially when sending commands con- secutively.

41

Image 41
Contents WJ-FS316 WJ-FS409 WJ-FS416 Lightning flash with arrowhead sym Contents Segment Screen FeaturesPreface Do not drop metallic parts through slots PrecautionsDo not attempt to disassemble the appliance Handle the appliance with careAlarm Reset Button Alarm Reset Power Switch Power ON/OFFAlarm Indicator Alarm WJ-FS316/FS416Sequence Button SEQ Spot/Multiscreen Selection ButtonIncrement/Decrement Buttons -, + 0Set Button SETRear View Displaying the Setup Menu Setup MenuSetup Menu Dynamic REC Alarm Setup MenuALM REC Mode ALM Display Auto ResetALM Output ALM BuzzerMLT OUT Mode Monitor Output Setup MenuSPT OUT Mode Multi OutputTitle Display Record Output Setup MenuSpot OUT Auto Skip Sequence Setup MenuREC Mode Step Assignment SEQ ModeMLT/SPT SEQ Setup System Setup MenuTitle Setup Spot OutputCAM SW Loss Title PosiPlayback Auto To erase a specific characterPWR on Multi PasswordPWR on Spot ON→Communication Setup SW Interval EncodeMounting in the Rack InstallationsVideo Multiplexer WJ-FS309/FS409 System ConnectionsBasic System Connection Connect the time lapse VCR as shown in the example below Connection with the Time Lapse VCRALARM/REMOTEDATA Camera GND Multi Connection with the WV-CU360 System Controller Connection with the MonitorsSpot ALARM/REMOTE ConnectorNC no Connection with the Alarm SensorsConnection with the Alarm Output Remote SW1 Connection with the Remote External SwitchesMonitoring the Camera Picture Operating ProceduresSpot Multiscreen SEQVCR CAM Multiscreen OUTStill Spot Picture Multiscreen Sequence Multiscreen PictureStill Multiscreen Picture Spot Playback Picture Recording on the Time LapseMonitoring the Playback Picture Still Spot Playback Picture Zoomed Spot Playback PicturePlayback Multiscreen Sequence Multiscreen Playback PictureStill Multiscreen Playback Picture Alarm Operation Alarm Control FunctionAlarm Input Manual Reset Alarm ResetAuto Reset External ResetCamera Switching Pulse Loss Display ALL ResetChannel Loss Alarm Other FunctionsData Format AppendixAscii Video Multiplexer to System ControllerAll camera channels in a multiscreen Standard Accessories SpecificationsPanasonic Canada Inc

WJ-FS409, WJ-FS316, WJ-FS416, WJ-FS309 specifications

Panasonic's WJ-FS309, WJ-FS416, WJ-FS316, and WJ-FS409 are robust digital video multiplexers designed to enhance surveillance systems. These models incorporate advanced technologies and features critical for effective video management, making them suitable for various applications, including retail security, transportation, and public safety.

The WJ-FS309 is known for its versatile functionality, allowing users to view and manage multiple camera feeds on a single display. It supports up to nine inputs, offering a compact solution for smaller installations. Its user-friendly interface simplifies operation, while features like real-time monitoring and on-screen display options enhance usability.

WJ-FS316 is an upgraded version, capable of accommodating 16 camera inputs. This model is equipped with a high-performance processor that ensures smooth video playback and rapid switching between feeds. It also features built-in motion detection, which alerts users to unusual activity, thereby increasing security effectiveness. Additionally, the WJ-FS316 supports a variety of output resolutions, providing flexibility for different display setups.

The WJ-FS409 stands out with its support for 4CIF resolution, ensuring high-quality video output essential for detailed surveillance. It also includes advanced video analysis capabilities, such as video motion detection and mask programming, which allow users to filter out unnecessary information, thus focusing on critical events. This feature is particularly useful in locations with high foot traffic, as it helps reduce the workload for security personnel.

The WJ-FS416 is a comprehensive solution that combines features from both the WJ-FS309 and WJ-FS409. It supports 16 channels and offers high-quality image processing, making it ideal for extensive surveillance systems. Its flexibility extends to network integration, allowing for seamless connectivity with existing security infrastructure. Users can remotely access camera feeds, creating a more dynamic monitoring experience.

Overall, these Panasonic models provide a robust and scalable approach to video surveillance. They incorporate essential technologies that streamline video management while ensuring high image quality and effective security monitoring. Through their thoughtful design and advanced features, the WJ-FS series underscores Panasonic's commitment to delivering reliable and innovative solutions for modern surveillance challenges.