ON: Enables the PLAYBACK AUTO mode.

OFF: Disables the PLAYBACK AUTO mode.

5. PASSWORD

This item lets you select whether to permit free or limited access to the Setup menus. When PASSWORD is set to ON, the operator must enter the password to access the menus.

1.Move the cursor to the PASSWORD parameter.

2.Select ON or OFF by pressing the + or button. The initial factory setting is OFF.

5-1. Password registration

Enter a 4-digit password consisting of numbers from 1 to 9 (except 0).

ON1111-9999:

Password required to access the Setup menus.

1.Select ON by pressing the + or button.

2.Move the cursor to the desired (first) digit by press- ing the A or B button.

3.Select the desired number by pressing the + or button.

4.Repeat steps 2 and 3 until all digits are registered.

OFF: No password required to access the Setup menus (access is free).

5-2. Reply to password request

If PASSWORD parameter is set to ON, the operator is requested to type the password to access the Setup menus.

1.Press the MENU/ESC button for 2 seconds or more. The password inquiry screen prompts you to type the password.

2.Type the 4-digit password by pressing the CAMERA SELECT buttons 1 through 9, and the A or B button.

3.The Setup menu appears if the typed password is cor- rect. If a wrong password is typed, the screen displays “NG” and returns to the screen before the MENU/ESC button was pressed.

4.To retry repeat steps 1 and 2.

5-3. Changing the password

The password currently registered can be changed as fol- lows.

1.Press the MENU/ESC button for 2 seconds or more to display the password inquiry screen. Then type in the current password by pressing the CAMERA SELECT buttons, and the A or B button. The SETUP menu appears.

2.In the SYSTEM SETUP menu, select ON for the PASS- WORD parameter.

3.Move the cursor to the first (desired) digit by pressing the A or B button.

4.Select the desired number by pressing the + or but- ton.

5.Repeat step 3 and 4 until all digits are registered.

6.After registration the new password is required when the operator accesses the SETUP menus.

6.PWR ON MULTI

This parameter lets you select a multiscreen output pattern for your startup screen. When the power is turned on, the picture is displayed in the selected pattern.

1.Move the cursor to the PWR ON MULTI parameter.

2.Select 1-16 (1-9 only for WJ-FS309/FS409), SPOT SEQ or QUAD-4A to 4D, 9 screen, 16 screen, MLT-SEQ The initial factory setting is QUAD-4A.

1-16:Spot picture of selected channel is displayed.

SPOT SEQ: A sequence of spot pictures is displayed.

QUAD-4A to 4D: 4-segment screen

9 screen: 9-segment screen

16 screen: 16-segment screen

MLT-SEQ:Multiscreen sequence

7.PWR ON SPOT

This parameter lets you select a Spot output pattern for your startup screen. When the power is turned on, the pic- ture is displayed in the selected pattern.

1.Move the cursor to the PWR ON SPOT parameter

2.Select 1-16 (1-9 only for WJ-FS309/FS409) or SPOT SEQ.

The initial factory setting is 1.

1-16:Spot picture of selected channel is displayed.

SPOT SEQ: A sequence of spot pictures is displayed.

19

Image 19
Contents WJ-FS316 WJ-FS409 WJ-FS416 Lightning flash with arrowhead sym Contents Preface FeaturesSegment Screen Handle the appliance with care PrecautionsDo not drop metallic parts through slots Do not attempt to disassemble the applianceWJ-FS316/FS416 Power Switch Power ON/OFFAlarm Reset Button Alarm Reset Alarm Indicator Alarm0Set Button SET Spot/Multiscreen Selection ButtonSequence Button SEQ Increment/Decrement Buttons -, +Rear View Displaying the Setup Menu Setup MenuSetup Menu ALM REC Mode Alarm Setup MenuDynamic REC ALM Buzzer Auto ResetALM Display ALM OutputMulti Output Monitor Output Setup MenuMLT OUT Mode SPT OUT ModeSpot OUT Record Output Setup MenuTitle Display REC Mode Sequence Setup MenuAuto Skip Step Assignment SEQ ModeSpot Output System Setup MenuMLT/SPT SEQ Setup Title SetupTo erase a specific character Title PosiCAM SW Loss Playback AutoON→ PasswordPWR on Multi PWR on SpotCommunication Setup SW Interval EncodeMounting in the Rack InstallationsBasic System Connection System ConnectionsVideo Multiplexer WJ-FS309/FS409 Connect the time lapse VCR as shown in the example below Connection with the Time Lapse VCRALARM/REMOTEDATA Camera GND Multi Connection with the WV-CU360 System Controller Connection with the MonitorsSpot ALARM/REMOTE ConnectorConnection with the Alarm Output Connection with the Alarm SensorsNC no Remote SW1 Connection with the Remote External SwitchesSEQ Operating ProceduresMonitoring the Camera Picture Spot MultiscreenVCR CAM Multiscreen OUTStill Spot Picture Still Multiscreen Picture Multiscreen PictureMultiscreen Sequence Monitoring the Playback Picture Recording on the Time LapseSpot Playback Picture Still Spot Playback Picture Zoomed Spot Playback PictureStill Multiscreen Playback Picture Multiscreen Playback PicturePlayback Multiscreen Sequence Alarm Input Alarm Control FunctionAlarm Operation External Reset Alarm ResetManual Reset Auto ResetOther Functions ALL ResetCamera Switching Pulse Loss Display Channel Loss AlarmVideo Multiplexer to System Controller AppendixData Format AsciiAll camera channels in a multiscreen Standard Accessories SpecificationsPanasonic Canada Inc

WJ-FS409, WJ-FS316, WJ-FS416, WJ-FS309 specifications

Panasonic's WJ-FS309, WJ-FS416, WJ-FS316, and WJ-FS409 are robust digital video multiplexers designed to enhance surveillance systems. These models incorporate advanced technologies and features critical for effective video management, making them suitable for various applications, including retail security, transportation, and public safety.

The WJ-FS309 is known for its versatile functionality, allowing users to view and manage multiple camera feeds on a single display. It supports up to nine inputs, offering a compact solution for smaller installations. Its user-friendly interface simplifies operation, while features like real-time monitoring and on-screen display options enhance usability.

WJ-FS316 is an upgraded version, capable of accommodating 16 camera inputs. This model is equipped with a high-performance processor that ensures smooth video playback and rapid switching between feeds. It also features built-in motion detection, which alerts users to unusual activity, thereby increasing security effectiveness. Additionally, the WJ-FS316 supports a variety of output resolutions, providing flexibility for different display setups.

The WJ-FS409 stands out with its support for 4CIF resolution, ensuring high-quality video output essential for detailed surveillance. It also includes advanced video analysis capabilities, such as video motion detection and mask programming, which allow users to filter out unnecessary information, thus focusing on critical events. This feature is particularly useful in locations with high foot traffic, as it helps reduce the workload for security personnel.

The WJ-FS416 is a comprehensive solution that combines features from both the WJ-FS309 and WJ-FS409. It supports 16 channels and offers high-quality image processing, making it ideal for extensive surveillance systems. Its flexibility extends to network integration, allowing for seamless connectivity with existing security infrastructure. Users can remotely access camera feeds, creating a more dynamic monitoring experience.

Overall, these Panasonic models provide a robust and scalable approach to video surveillance. They incorporate essential technologies that streamline video management while ensuring high image quality and effective security monitoring. Through their thoughtful design and advanced features, the WJ-FS series underscores Panasonic's commitment to delivering reliable and innovative solutions for modern surveillance challenges.