Panasonic TH-103PF10EK manual PC Input Terminals connection, Connections

Page 9

Connections

PC Input Terminals connection

COMPUTER

Conversion adapter (if necessary)

RGB

AUDIO

PC IN

Mini D-sub 15p

PC cable

Audio

Stereo plug

 

Connect a cable which matches

the audio output terminal on the computer.

Notes:

Due to space limitations, occasionally you may have trouble connecting Mini D-sub 15P cable with ferrite core to PC input Terminal.

Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz and vertical scanning frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 lines.)

The display resolution is a maximum of 1,440 × 1,080 dots when the aspect mode is set to “4:3”, and 1,920 × 1,080 dots when the aspect mode is set to “16:9”. If the display resolution exceeds these maximums, it may not be possible to show fine detail with sufficient clarity.

The PC input terminals are DDC2B-compatible. If the computer being connected is not DDC2B-compatible, you will need to make setting changes to the computer at the time of connection.

Some PC models cannot be connected to the set.

There is no need to use an adapter for computers with DOS/V compatible Mini D-sub 15P terminal.

The computer shown in the illustration is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

Do not set the horizontal and vertical scanning frequencies for PC signals which are above or below the specified frequency range.

Component Input is possible with the pin 1, 2, 3 of the Mini D-sub 15P Connector.

To use sync input VBS signals, use the connector which incorporates a 75-ohm termination resistance and which is available on the market, for the connection of the HD connector where the VBS signals are to be input.

Change the “Component/RGB-in select” setting in the “Setup” menu to “Component”

(when Component signal connection) or “RGB” (when RGB signal connection). (see page 39)

Signal Names for Mini D-sub 15P Connector

5 4 3 2 1

10

9

 

8

7

6

15

14

 

13

12

 

11

Pin Layout for PC Input Terminal

Pin No.

Signal Name

Pin No.

Signal Name

Pin No.

Signal Name

1

R (PR/CR)

6

GND (Ground)

11

NC (not connected)

2

G (Y)

7

GND (Ground)

12

SDA

 

 

 

 

 

 

3

B (PB/CB)

8

GND (Ground)

13

HD/SYNC

 

 

 

 

 

 

4

NC (not connected)

9

+5 V DC

14

VD

 

 

 

 

 

 

5

GND (Ground)

10

GND (Ground)

15

SCL

9

Image 9
Contents Operating Instructions High Definition Plasma DisplayModel No. TH-103PF10EK EnglishTable of Contents Important the Moulded Plug Important Safety NoticeSetup Safety PrecautionsDo not place any objects on top of the Plasma Display Transport only in upright positionSafety Precautions When using the Plasma DisplayIf problems occur during use Take steps to prevent toppling Clean the power cable regularly to prevent it becoming dustyAccessories Accessories SupplyRemote Control Batteries Audio OUT Terminals connection ConnectionsAC cord fixing Close OpenSignal Names for Mini D-sub 15P Connector PC Input Terminals connectionConnections Serial Terminals connection CommandCommunication parameters Basic format for control dataSignal Name DVI-D Input Connector Pin LayoutsDVI-D connection Component / RGB connectionConnecting the AC cord plug to the Plasma Display Power On / OffConnecting the plug to the Wall Outlet Right side surfaceSelecting the input signal Initial selectionsSelecting the On-Screen Menu Language Basic Controls Basic Controls See page 23 On-Screen Menu DisplaysOn-Screen Menu Displays SignalAspect Controls Normalisation Adjusting Pos. /SizeAdjusting Pos. /Size Multi PIP Options Advanced PIPNormal Picture AdjustmentsDynamic CinemaPicture Adjustments Advanced settingsSound Adjustment SDI Sound Output Sound AdjustmentMute On OffDisplay the operation guide Digital ZoomSelect the area of the image to be enlarged Select the magnification required for the enlarged displayPresent Time Setup Present Time Setup / Set up TimerPresent Time Setup / Set up Timer Set up TimerStart setting Mode selectionScreensaver For preventing image retention Reversal / Scroll selectionSetup of Screensaver Time Reduces screen image retentionScreensaver For preventing image retention Side Panel Adjustment Reduces power consumption Customizing the Input labelsAddition sign Selected Input How to Setup Multi Display Setup for Multi DisplayDisplay Number locations for each arrangement Examples Setup for Multi DisplayID remote control button operation ID Remote Control FunctionID Cancellation AI-synchronizationHow to setup Portrait Set up for PortraitViewing Area / Location Set up for PortraitSetup for Input Signals Component / RGB-in select3D Y/C Filter For Ntsc AV images NR / Block NR / Mosquito NR Setup for Input SignalsCinema reality Colour system / Panasonic AutoSync Setting RGB sync signalFreq. kHz / V-Freq. Hz Displays the H Horizontal / V Vertical frequenciesEffect Adjustments Options AdjustmentsOptions Adjustments Initial Power Off-timerOff Nullify all the settings adjusted On Sets the colour temperature for TV studioNormalization Weekly Command Timer Weekly Command TimerPress to select Time / Command Shipping condition Plasma Display panel TroubleshootingDVI-D DVI-D/COMPONENT/RGB/PC input signalsCommand list of Weekly Command Timer Specifications Memo Memo For business users in the European Union Customer’s RecordSales and Support Information Customer Care Centre