JVC SR-9168U appendix Alarm Input/Power Loss Data Display, Hour Meter Display, Menu button

Page 16

4 MONITOR ON-SCREEN DISPLAY

REC STOP/EJECT REC CHECK

PAUSE/

REVERSE STILL PLAY

REWFF

 

 

[SHIFT +/–] buttons

[MENU] button

 

 

 

 

 

 

 

SR-9168U

VIDEO CASSETTE RECORDER

 

 

 

OPERATE

 

 

 

 

COUNT/

MENU

SHIFT/TRACKING

RESET

 

CLOCK

 

/CANCEL

OPE. LOCK

TIME

TIMER

SET/V.LOCK

AL/PL

 

MODE

REC

 

RESET

ON

[AL/PL RESET]

[SET +/–] buttons button

4-3 Alarm Input/Power Loss Data Display

The dates and times of up to nine (9) alarm inputs or power losses (failures) can be displayed.

Alarm input data screen

1Turn on the VCR and monitor. Make sure the Stop mode is engaged.

 

ALARM IN

A L – 0 0 1

2 0 : 3 0

9 – 6 – 9 9

A L – 0 0 2

2 1 : 4 4

1 0 – 6 – 9 9

A L – – – – – – : – – – – – – – – – –

A L – – – – – – : – – – – – – – – – –

A L – – – – – – : – – – – – – – – – –

A L – – – – – – : – – – – – – – – – –

A L – – – – – – : – – – – – – – – – –

A L – – – – – – : – – – – – – – – – –

A L – – – – – – : – – – – – – – – – –

PRESS (AL / PL)

TO

ALL RESET

PRESS (MENU)

TO

END

Hour

 

Year

Minute Day

Month

First alarm Second alarm

2Press the [MENU] button to display the main menu.

3Press the [SHIFT +] or [SHIFT -] button to select ALARM IN or POWER LOSS.

To display alarm input data, select ALARM IN. To display power failure data, select POWER LOSS.

4Press the [SET +] or [SET -] button to display the selected data (alarm input or power loss).

When 10 or more alarm input or power loss data items have been stored, subsequent data will replace earlier items, beginning from the second item.

Power loss (failure) data screen

5 Press the [MENU] button twice to end menu operation

POWER LOSS

P L – 0 0 1

2 1 : 3 0

9 –

6 – 9 9

P L – 0 0 2

1 7 : 4 4

1 0 –

7 – 9 9

P L – – – – – – : – – – – – – – – – –

P L – – – – – – : – – – – – – – – – –

P L – – – – – – : – – – – – – – – – –

P L – – – – – – : – – – – – – – – – –

P L – – – – – – : – – – – – – – – – –

P L – – – – – – : – – – – – – – – – –

P L – – – – – – : – – – – – – – – – –

PRESS (AL / PL) TO ALL RESET PRESS (MENU) TO END

First power failure Second power failure

and restore the normal screen.

Resetting alarm input/power loss (failure) data

When the "AL" (alarm) display is off and the VCR is in the normal screen mode, press the [AL/PL RESET] button to reset the alarm input and power loss data stored in memory.

4-4 Hour Meter Display

Drum rotating time is displayed in the form of an hour meter. Use this data to schedule maintenance.

Hour meter screen

HOUR METER

DRUM ON 02345H

Drum rotating time

PRESS (MENU) TO END

Operation

1Turn on the VCR and monitor. Make sure the Stop mode is engaged.

2Press the [MENU] button to display the main menu.

3Press the [SHIFT +] or [SHIFT -] button to select HOUR METER.

4Press the [SET +] or [SET -] button to display the hour meter (drum rotating time).

5Press the [MENU] button twice to end menu operation and restore the normal screen.

16

Image 16
Contents Video Cassette Recorder SR-9168UINSTRUCTIONS For Customer UseSafety Precautions InformationContents Major Features Periodical MaintenancePeriodic Maintenance IntroductionIntroduction PrecautionsDaily Inspection Controls and Connectors Front PanelControls and Connectors Display Rear Panel Series recording signal input VCR activation signal inputClock reset signal input Connecting the wires to the terminals 9 toConnecting to a Camera ConnectionsConnecting a System Using a Sequential Switcher Video output Camera Sequential switcherConnections Video camerasConnecting the Rear Panel Input/Output Terminal Connections Position setting Monitor ON-SCREEN DisplayOn-Screen Display in the Time/Date and Record Modes DisplayMain Menu Display Monitor ON-SCREEN DisplayOperation Alarm Input/Power Loss Data Display Hour Meter DisplayMenu button SET +/- buttons buttonFunction Menu Switch Setting PreparationSetting of the Function Menu Switches Contents of the Function Menu SwitchesIndex OFF SearchCamera SW OFF FieldParameter Setting Alarm/sensorRS-232C Date and Time Setting Auto power onPreparation Cassette Loading/UnloadingSet the date and time using the Clock Adjust menu screen Date/time setting screenPreparation Set the date and time on the front panel displaySelection of Record/Play Mode Mode indicationSummer Time Compensation During daylight savings timeRecording PreparationRecording RecordingTimer Recording Setting the daily timerVCRs display BlinkingSetting the weekly timer Cancel program setting screen Canceling timer programmingTo cancel programmed data To stop timer programmingChanging a preset timer program Using the VCR in the Timer Record Standby modeAlarm Recording Alarm recording will not start from the Pause mode6H EP,18H RecordingTape stops Press the Operate button to turn the operating mode onStops Recording mode setting screen Sensor RecordingRepeat Sensor recording continues from Beginning of the tapeRepeat Recording Auto Recording Check functionSeries Recording ConnectionsOperations Rear panelRecording with External VCR Activation Signal VCR control signal ground signalConnection OperationHow to Restore Recording After Power Failure External Timer RecordingVTR mode 1 setting screen Tape End BuzzerFunction menu switch settings Set to on to search the alarm-recorded positions index codePlayback To stop playbackPlayback and SPECIAL-EFFECTS Playback Special-Effects PlaybackStill and field by field advance Reverse playbackTracking/V. Lock Adjustment Index SearchPress the V. Lock +/- button to minimize vertical jitter IndexError Indication TroubleshootingError Contents VCR operation Measures Troubleshooting No Error IndicationInstallation of the SA-K97U SA-K97U Specifications Pin no Signals Operations Direction of signalsOptional SA-K97U RS-232C Interface Board Parity check Stop bit BitJVC base table SA-K97U RS-232C Protocol & CommandsJVC This section provides technical data for programmers VCR control commandsVCR setting commands Mode 1st byte 2nd byte1st byte 2nd byte 3rd byteCancel 67H AL/PL Reset E1HCount Reset E2H 8EHCommands for VCR status verification 1st/2nd byte3rd byte 5th byte 4th byte 6th byteContents of 5th byte BIT 0/1/2/3 Speed Code 4th byteOthers Input data correction/Error cancellation Commands reference chartAppendixes Rear Panel’s Input/OutputSpecifications AppendixesSR-9168U Video Cassette Recorder Victor Company of JAPAN, Limited