7 RECORDING
7-8 Recording with External VCR Activation Signal
Recording start/stop can be controlled externally by inputting a VCR activation signal to the [SERIES/CLOCK IN] terminal on the
Rear panel
To [COM] terminal
To [SERIES/CLOCK IN] terminal |
External control equipment
Connection
VCR control signal (ground signal)
Connect the [SERIES/CLOCK IN] terminal and [COM] terminal on the
LV: 0 V
Start of recording | Stop or power off |
Operation
|
|
|
| VTR MODE 2 |
|
|
|
|
|
|
| (SUMMER TIME) | OFF |
|
|
TERMINAL |
|
|
| (TERMINAL SEL 1) | EXT |
| Set to EXT. |
|
|
| |||||
SEL 1 |
| (TERMINAL SEL 2) | WARN |
| (External | ||
|
|
|
| (REC REMAIN) | OFF |
| recording |
|
|
|
| (COUNT END) | OFF |
| |
|
|
|
|
| function) | ||
|
|
|
|
|
|
|
PRESS (SHIFT, SET)
PRESS (MENU) TO END
VCR mode 2 setting screen
•When the [TIMER] indication is lit or the function is lit or the function menu switch [TAPE END MODE] on the VTR mode 1 setting screen is set to “REPEAT”, this function is disabled.
•If a VCR activation signal is input while the unit is already recording (started with the [REC] button), recording continues and stops when the activation signal is no longer input.
1Set the function menu switch <TERMINAL SEL 1> to “EXT” to use the external recording function.
2Press the MENU button to switch the
3Load a cassette with a safety tab in place and engage the Stop mode, the Pause mode or turn the operating mode off.
•When a VCR activation signal (ground input) is input to the rear panel’s [SERIES/CLOCK IN] terminal, recording starts automatically and continues for as long as the activation signal is input.
When the activation signal stops, the Stop mode is engaged.
•When the activation signal is input again, recording starts.
36