5. Configuring The Receiver
In the setup mode, the units of depth measurement, time, date, and date format can be set. The receiver can be configured to detect only certain frequencies and/or specific utility markers (3M™ Dynatel™ Receivers
A. Selecting Depth Units
Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] + [SK:5] + >>More [SK:d] +
>>More [SK:h] + [SKToggle:i]
•The soft key command will toggle between inches (in), centimeters (cm), and feet/inches
B. Setting the Receiver Clock
Set the time, date, and date format of the receiver. Depth and Current measurements are time and date stamped, as well as read and write marker information (iD units only).
Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] + [SK:5] + [SK:b]
•Press the left/right arrow [SK] to highlight the digit of the date or time to change.
•Press the + or - [SK] to increment or decrement.
•When the date format is highlighted, the format will toggle between mm/dd/yy and dd/mm/yy.
•Press Menu/OK [5] to save.
C. Selecting a Language
Menu/OK [5:Toggle to MAIN MENU] + >>More [SK:4] + [SK:5] + [SKToggle:a]
The soft key command will toggle between available languages. Alternate languages can be uploaded to the receiver using the 3M™ Dynatel™ PCTools Software. The 3M™ Dynatel™ PC Tool Kit Software is available free of charge at www.3M.com/dynatel under the Software section; 2550/2573/2250M/2273M/1420 Locator PC Tools xx.x.x (EXE xx.xMB).
17 |