Kathrein MSK 125 manual Command Overview for Command Byte, Hex Command ID Description

Page 29

SAT

COMMAND OVERVIEW FOR COMMAND BYTE

The MSK 125 can send commands based on DiSEqCTM1.0 but cannot receive them. All commands requiring DiSEqCTM2.0 (send and receive) are greyed out in the table.

Commands in bold letters are preferred for Kathrein switching matrices.

Hex

Command ID

Description

Number of

Byte

 

 

Data Byte

00

Reset

Reset DiSEqCTM microcontroller

-

01

Clr Reset

Delete reset flag

-

02

Standby

Turn off peripheral power unit

-

03

Power on

Turn on peripheral power unit

-

04

Set Contend

Set the contention flag

-

05

Contend

Response only if contention flag has been set

-

06

Clr Contend

Delete the contention flag

-

07

Address

Response only if contention flag has not been set

-

08

Move C

Change address if contention flag has been set

1

09

Move

Change address if contention flag has not been set

1

10

Status

Read status register flags

-

11

Config

Read configuration flags

-

14

Switch 0

Read switching status flag (commited port)

-

15

Switch 1

Read switching status flag (uncommited port)

-

16

Switch 2

Expansion option

-

17

Switch 3

Expansion option

-

20

Set LO

Call up low local oscillator frequency

-

21

Set VR

Call up vertical polarisation or clockwise circular polarisation

-

22

Set Pos A

Select satellite position A

-

23

Set S0A

Select switch option A

-

24

Set Hi

Call up high local oscillator frequency

-

25

Set HL

Call up horizontal polarisation or anti-clockwise circular

-

 

 

polarisation

 

26

Set Pos B

Select satellite position B

-

27

Set S0B

Select switch option B

-

28

Set S1A

Call up matrix S1 input A (input B not active)

-

29

Set S2A

Call up matrix S2 input A (input B not active)

-

2A

Set S3A

Call up matrix S3 input A (input B not active)

-

2B

Set S4A

Call up matrix S4 input A (input B not active)

-

2C

Set S1B

Call up matrix S1 input B (input A not active)

-

2D

Set S2B

Call up matrix S2 input B (input A not active)

-

2E

Set S3B

Call up matrix S3 input B (input A not active)

-

2F

Set S4B

Call up matrix S4 input B (input A not active)

-

30

Sleep

All bus commands are ignored except for Awake

-

31

Awake

Bus commands are accepted again

-

38

Write N0

Set port group 0

1

29

Image 29
Contents MSK Validity of this Operating Manual General Safety InstructionsFOREWORD/IMPORTANT Instructions Contents FM Measurement Maintenance Storing Device SettingsCustomer Service Features Technical Data Technical AppendixMeaning of Symbols Safety InstructionsSafety Instructions Product PackageFunctionality 8PSK FunctionLC Display Operating and Display ElementsTFT Colour Display LED DisplaySource selection Measurements LC display TFT colour displayInput block Alphanumeric input Overview of Keypad CommandsButton Operating and Display Elements Connections Fan Ear phones Loudspeakers Battery fuse DC supplyFront View Side ViewRF Input Socket External DC Power SupplyUSB Port SD CardGetting Started Switch on Switching OFF Setup MenuSetup Menu Settings Default Setup Settings AT Time of Shipment Mains and Battery OperationParameter Setting Mains OperationBattery Operation Command Overview of SAT Frequency Entry SAT ANALOGUE/DVB-S2 SwitchSAT Analogue Satellite ReceptionCommand overview for LNB voltage Following voltages can be called up via button commandLNB Voltage and 22 KHZ CHANGE-OVER Button LNB voltageLevel overflow and underflow Sound Carrier Frequency SettingSAT Analogue Level Measurement Select Sound Carrier Frequency in MHz BandwidthDigital SAT Reception Following voltages can be Button Called up via button commandCommand overview for LNB voltage SAT DVB-S2 Level Measurement Setting DVB-S2 Demodulation ParametersDiseqctm Digital Satellite Equipment Control Button Hex code Command Overview for DiseqctmSAT-CTRL menu DiSEqCTM menu Hex Byte Description Command Overview for Framing ByteCommand Overview for Address Byte Hex Command ID Description Command Overview for Command ByteSwitch Read switching status flag commited port ByteOrbit Polarisation Switch Position Data Byte Low Band Command Overview for Data ByteSimple DISEQCTM, Tone Burst List of Single Cable Diseqctm CommandCommand Overview for Simple Diseqctm Mpeg Image Representation in DVB-S2 DVB-S2 MER, BER and Offset MeasurementCalling up DVB-S2 measurement Press to exit digital receptionLocating Satellites Command overviewFinding Individual Reception Frequencies Command overview for findingHF Standard Switch Analogue Cable Demod Menu Analogue CABLE/DVB C SwitchTV Measurement Analogue TV Cable ReceptionFrequency Display and Entry Command Overview for TV Channel EntryChannel Display and Entry Cable Analogue Level Measurement Command Overview for TV Frequency EntryAudio Carrier Spacing and Level Command Overview for Measure TV Audio Carrier FrequencyLevel Overflow and Underflow StandardSelect Soundcarrier Digital TV Cable Reception Channel Display and Entry Setting DVB-C Demodulation Parameters LC display for DVB-C signals Level Measurement of DVB-C/DVB-T/H SignalsDVB-C/DVB-T/H MER, BER and Offset Measurement To call up DVB-C/DVB-T/H measurementMpeg Image Representation in DVB-C HF Standard Switch Terrestrial Analogue TERRESTRIAL/DVB T/H SwitchHF Standard Switch Analogue Terrestrial TV ReceptionChannel Display and Entry Command Overview for TV Frequency Entry HF Standard Switch DVB-T Setting DVB-T/H Demodulation ParametersSelect the required HF bandwidth by using the digit buttons Digital Terrestrial TV ReceptionChannel Display and Entry DVB-C/DVB-T/H MER, BER and Offset Measurement Mpeg Image Representation in DVB-T LC display for DVB-T signalsFinding Individual Reception Frequencies Nicam Audio BIT Error Rate Measurement Command Overview for FM Frequency Entry FM SwitchFM Measurement Level MeasurementCommand Overview for Find TV Spectrum Spectrum MeasurementSAT Spectrum Spectrum Measurement FM Spectrum Storing Device Settings Storing Device SettingsDeleting Device Settings TFT display LC displayStoring Measurement Results in the Device Memory Storing Measurement ResultsSpectrum Memory Full Only 10 Spec. Possible TFT displayStoring Measurement Results on the SD Card Deleting Measurement Results from the Device MemoryStoring Measurement Results Entering the Start Line for Automatic Measuring Data LoggerEntering the Stop Line for Automatic Measuring Starting and Interrupting Automatic MeasuringMessage Storing the Data Logger Measurement Results on the SD CardMaintenance Technical Customer Support Customer ServiceFeatures RF component Technical DataLevel measuring component +14.1 dB SIGNAL-TO-NOISE RatioTechnical Appendix Command SET for Kathrein Matrices Diseqctm Commands for Kathrein MatricesCommand SET for EXR 20 Kathrein Matrix Command SET for EXR 22 Kathrein MatrixChannel UND Frequency TABLE, Standard B/G Frequency in MHZ Channel TablesVHF UHF Channel UND Frequency TABLE, Standard L Frequency in MHZVII Channel UND Frequency TABLE, D/K Standard Frequency in MHZChannel UND Frequency TABLE, I Standard Frequency in MHZ This is done as follows Calculation of SAT if Frequency Using the MSKOscillation frequency is made up as follows Hence the values for ARD Das Erste arePage Page 936.3474/A/0409/ZWT Technical data subject to change