STORING MEASUREMENT RESULTS

If you wish to copy a complete storage range to the SD card, enter the last storage place

before you press

for the second time,

e.g.: “from 02 - 15”.

 

The storage places “02” to “15” are

stored on the SD card under a serial number. The LC display confirms the storing with the message “STORED TO SD-CARD”.

You can either transfer the measurement results on the SD card to a PC via USB connection or read, manage and print out the SD card directly on your PC!

The required conversion program is available on our web site. Please go to “http://www.kathrein.de”, then to “Service”, “Software and Downloads”, “Measuring-Instrument”, “MSK 125”.

62

Image 62
Contents MSK Validity of this Operating Manual General Safety InstructionsFOREWORD/IMPORTANT Instructions Contents FM Measurement Customer Service Storing Device SettingsMaintenance Features Technical Data Technical AppendixSafety Instructions Safety InstructionsMeaning of Symbols Product PackageFunctionality Function 8PSKTFT Colour Display Operating and Display ElementsLC Display LED DisplayTFT colour display Source selection Measurements LC displayInput block Alphanumeric input Overview of Keypad CommandsButton Operating and Display Elements Front View Fan Ear phones Loudspeakers Battery fuse DC supplyConnections Side ViewUSB Port External DC Power SupplyRF Input Socket SD CardGetting Started Switch on Switching OFF Setup MenuSetup Menu Settings Parameter Setting Mains and Battery OperationDefault Setup Settings AT Time of Shipment Mains OperationBattery Operation SAT SAT ANALOGUE/DVB-S2 SwitchCommand Overview of SAT Frequency Entry Analogue Satellite ReceptionLNB Voltage and 22 KHZ CHANGE-OVER Following voltages can be called up via button commandCommand overview for LNB voltage Button LNB voltageLevel overflow and underflow Sound Carrier Frequency SettingSAT Analogue Level Measurement Frequency in MHz Bandwidth Select Sound CarrierDigital SAT Reception Called up via button command Following voltages can be ButtonCommand overview for LNB voltage SAT DVB-S2 Level Measurement Setting DVB-S2 Demodulation ParametersDiseqctm Digital Satellite Equipment Control Command Overview for Diseqctm Button Hex codeSAT-CTRL menu DiSEqCTM menu Hex Byte Description Command Overview for Framing ByteCommand Overview for Address Byte Switch Read switching status flag commited port Command Overview for Command ByteHex Command ID Description ByteCommand Overview for Data Byte Orbit Polarisation Switch Position Data Byte Low BandSimple DISEQCTM, Tone Burst List of Single Cable Diseqctm CommandCommand Overview for Simple Diseqctm Calling up DVB-S2 measurement DVB-S2 MER, BER and Offset MeasurementMpeg Image Representation in DVB-S2 Press to exit digital receptionCommand overview Locating SatellitesCommand overview for finding Finding Individual Reception FrequenciesTV Measurement Analogue CABLE/DVB C SwitchHF Standard Switch Analogue Cable Demod Menu Analogue TV Cable ReceptionFrequency Display and Entry Command Overview for TV Channel EntryChannel Display and Entry Command Overview for TV Frequency Entry Cable Analogue Level MeasurementLevel Overflow and Underflow Command Overview for Measure TV Audio Carrier FrequencyAudio Carrier Spacing and Level StandardSelect Soundcarrier Digital TV Cable Reception Channel Display and Entry Setting DVB-C Demodulation Parameters DVB-C/DVB-T/H MER, BER and Offset Measurement Level Measurement of DVB-C/DVB-T/H SignalsLC display for DVB-C signals To call up DVB-C/DVB-T/H measurementMpeg Image Representation in DVB-C HF Standard Switch Analogue TERRESTRIAL/DVB T/H SwitchHF Standard Switch Terrestrial Analogue Terrestrial TV ReceptionChannel Display and Entry Command Overview for TV Frequency Entry Select the required HF bandwidth by using the digit buttons Setting DVB-T/H Demodulation ParametersHF Standard Switch DVB-T Digital Terrestrial TV ReceptionChannel Display and Entry DVB-C/DVB-T/H MER, BER and Offset Measurement LC display for DVB-T signals Mpeg Image Representation in DVB-TFinding Individual Reception Frequencies Nicam Audio BIT Error Rate Measurement FM Measurement FM SwitchCommand Overview for FM Frequency Entry Level MeasurementCommand Overview for Find TV Spectrum Spectrum MeasurementSAT Spectrum Spectrum Measurement FM Spectrum Deleting Device Settings Storing Device SettingsStoring Device Settings TFT display LC displaySpectrum Memory Full Only 10 Spec. Possible Storing Measurement ResultsStoring Measurement Results in the Device Memory TFT displayDeleting Measurement Results from the Device Memory Storing Measurement Results on the SD CardStoring Measurement Results Data Logger Entering the Start Line for Automatic MeasuringStarting and Interrupting Automatic Measuring Entering the Stop Line for Automatic MeasuringStoring the Data Logger Measurement Results on the SD Card MessageMaintenance Customer Service Technical Customer SupportFeatures Technical Data RF componentLevel measuring component +14.1 dB SIGNAL-TO-NOISE RatioTechnical Appendix Command SET for EXR 20 Kathrein Matrix Diseqctm Commands for Kathrein MatricesCommand SET for Kathrein Matrices Command SET for EXR 22 Kathrein MatrixChannel Tables Channel UND Frequency TABLE, Standard B/G Frequency in MHZChannel UND Frequency TABLE, Standard L Frequency in MHZ VHF UHFChannel UND Frequency TABLE, D/K Standard Frequency in MHZ VIIChannel UND Frequency TABLE, I Standard Frequency in MHZ Oscillation frequency is made up as follows Calculation of SAT if Frequency Using the MSKThis is done as follows Hence the values for ARD Das Erste arePage Page 936.3474/A/0409/ZWT Technical data subject to change