FEATURES

Level measurement of analogue and digital TV signals (TV, Sat, FM, DVB-S(2), DVB-C, DVB-T, DVB-H (2k, 8k mode))

Image representation of analogue and digital TV signals

BER/MER measurement and display

5.7“-TFT colour display, transflective (640 x 480 pixels)

Two-line 22-character LCD

Spectrum analysis

Sat Finder function

Acoustic signal tone for antenna alignment

Level indication in dBµV or optionally dBmV

Automatic measuring range selection

Direct frequency and channel input

Measurement and display of remote feed current

Sound carrier measurement (TV)

Audio carrier and BER measurement

Sound control by built-in speaker

Stereo head phone socket

DiSEqCTM1.0 control signal

Memory for signal meter settings

Memory for measured values (SD card), reading via USB possible

Data Logger function

Interface for software updates

Scart socket, bidirectional, (CVBS, Audio)

Mains or battery operation possible

Included in delivery: Power unit, power cable, BNC measurement cable with adapters (2 x BNC socket - F socket, 1 x BNC socket - F connector, 1 x BNC socket - IEC socket, 1 x BNC socket - IEC connector)

A 12 V vehicle supply cable can be obtained through our customer service (company ESC, address see page 67) (order no.: 19700841BF).

68

Image 68
Contents MSK Validity of this Operating Manual General Safety InstructionsFOREWORD/IMPORTANT Instructions Contents FM Measurement Storing Device Settings MaintenanceCustomer Service Features Technical Data Technical AppendixSafety Instructions Meaning of SymbolsSafety Instructions Product PackageFunctionality Function 8PSKOperating and Display Elements LC DisplayTFT Colour Display LED DisplayTFT colour display Source selection Measurements LC displayInput block Alphanumeric input Overview of Keypad CommandsButton Operating and Display Elements Fan Ear phones Loudspeakers Battery fuse DC supply ConnectionsFront View Side ViewExternal DC Power Supply RF Input SocketUSB Port SD CardGetting Started Switch on Switching OFF Setup MenuSetup Menu Settings Mains and Battery Operation Default Setup Settings AT Time of ShipmentParameter Setting Mains OperationBattery Operation SAT ANALOGUE/DVB-S2 Switch Command Overview of SAT Frequency EntrySAT Analogue Satellite ReceptionFollowing voltages can be called up via button command Command overview for LNB voltageLNB Voltage and 22 KHZ CHANGE-OVER Button LNB voltageLevel overflow and underflow Sound Carrier Frequency SettingSAT Analogue Level Measurement Frequency in MHz Bandwidth Select Sound CarrierDigital SAT Reception Called up via button command Following voltages can be ButtonCommand overview for LNB voltage SAT DVB-S2 Level Measurement Setting DVB-S2 Demodulation ParametersDiseqctm Digital Satellite Equipment Control Command Overview for Diseqctm Button Hex codeSAT-CTRL menu DiSEqCTM menu Hex Byte Description Command Overview for Framing ByteCommand Overview for Address Byte Command Overview for Command Byte Hex Command ID DescriptionSwitch Read switching status flag commited port ByteCommand Overview for Data Byte Orbit Polarisation Switch Position Data Byte Low BandSimple DISEQCTM, Tone Burst List of Single Cable Diseqctm CommandCommand Overview for Simple Diseqctm DVB-S2 MER, BER and Offset Measurement Mpeg Image Representation in DVB-S2Calling up DVB-S2 measurement Press to exit digital receptionCommand overview Locating SatellitesCommand overview for finding Finding Individual Reception FrequenciesAnalogue CABLE/DVB C Switch HF Standard Switch Analogue Cable Demod MenuTV Measurement Analogue TV Cable ReceptionFrequency Display and Entry Command Overview for TV Channel EntryChannel Display and Entry Command Overview for TV Frequency Entry Cable Analogue Level MeasurementCommand Overview for Measure TV Audio Carrier Frequency Audio Carrier Spacing and LevelLevel Overflow and Underflow StandardSelect Soundcarrier Digital TV Cable Reception Channel Display and Entry Setting DVB-C Demodulation Parameters Level Measurement of DVB-C/DVB-T/H Signals LC display for DVB-C signalsDVB-C/DVB-T/H MER, BER and Offset Measurement To call up DVB-C/DVB-T/H measurementMpeg Image Representation in DVB-C Analogue TERRESTRIAL/DVB T/H Switch HF Standard Switch TerrestrialHF Standard Switch Analogue Terrestrial TV ReceptionChannel Display and Entry Command Overview for TV Frequency Entry Setting DVB-T/H Demodulation Parameters HF Standard Switch DVB-TSelect the required HF bandwidth by using the digit buttons Digital Terrestrial TV ReceptionChannel Display and Entry DVB-C/DVB-T/H MER, BER and Offset Measurement LC display for DVB-T signals Mpeg Image Representation in DVB-TFinding Individual Reception Frequencies Nicam Audio BIT Error Rate Measurement FM Switch Command Overview for FM Frequency EntryFM Measurement Level MeasurementCommand Overview for Find TV Spectrum Spectrum MeasurementSAT Spectrum Spectrum Measurement FM Spectrum Storing Device Settings Storing Device SettingsDeleting Device Settings TFT display LC displayStoring Measurement Results Storing Measurement Results in the Device MemorySpectrum Memory Full Only 10 Spec. Possible TFT displayDeleting Measurement Results from the Device Memory Storing Measurement Results on the SD CardStoring Measurement Results Data Logger Entering the Start Line for Automatic MeasuringStarting and Interrupting Automatic Measuring Entering the Stop Line for Automatic Measuring Storing the Data Logger Measurement Results on the SD Card MessageMaintenance Customer Service Technical Customer SupportFeatures Technical Data RF componentLevel measuring component +14.1 dB SIGNAL-TO-NOISE RatioTechnical Appendix Diseqctm Commands for Kathrein Matrices Command SET for Kathrein MatricesCommand SET for EXR 20 Kathrein Matrix Command SET for EXR 22 Kathrein MatrixChannel Tables Channel UND Frequency TABLE, Standard B/G Frequency in MHZChannel UND Frequency TABLE, Standard L Frequency in MHZ VHF UHFChannel UND Frequency TABLE, D/K Standard Frequency in MHZ VIIChannel UND Frequency TABLE, I Standard Frequency in MHZ Calculation of SAT if Frequency Using the MSK This is done as followsOscillation frequency is made up as follows Hence the values for ARD Das Erste arePage Page 936.3474/A/0409/ZWT Technical data subject to change