Kathrein MSK 125 manual Storing Measurement Results in the Device Memory, TFT display

Page 60

STORING MEASUREMENT RESULTS

STORING MEASUREMENT RESULTS IN THE DEVICE MEMORY

TFT display

LC display

Note

First select the measuring job and perform the measurement!

The Memory Explorer command displays the stored measuring results on the TFT display.

Use the Up and Down buttons to go a page up or down in the screen content.

Opens the entry field on the LC display to determine a storage place for the new measurement result.

...

Enter storage place 00 ... 99.

 

From 00 to 99 every measurement can be stored

 

individually.

Complete - the measurement results have been stored in the device.

Up to 10 spectrum images can be stored. You can select any storage place (storage number) of your choice. If you try to store more than 10 spectrum images, the following message will be displayed:

Spectrum Memory Full!

Only 10 Spec. Possible

You then need to delete at least 1 spectrum storage place (see next page).

RECOVERING MEASUREMENT RESULTS FROM THE DEVICE MEMORY

TFT display

394.00 MHz CABLE D

LC display

 

The Memory Explorer command displays the

 

stored measuring results on the TFT display.

 

Use the Up and Down buttons to go a page up

 

or down in the screen content.

 

Opens the entry field on the LC display for entry

 

of the storage place where the measurement

 

results are to be retrieved.

...

Enter storage place 00 ... 99.

 

From 00 to 99 any storage place can be called

 

up.

 

The measurement results are indicated on the TFT

 

display (example: measurement result no.: 02).

60

Image 60
Contents MSK General Safety Instructions FOREWORD/IMPORTANT InstructionsValidity of this Operating Manual Contents FM Measurement Storing Device Settings MaintenanceCustomer Service Features Technical Data Technical AppendixSafety Instructions Meaning of SymbolsSafety Instructions Product PackageFunctionality Function 8PSKOperating and Display Elements LC DisplayTFT Colour Display LED DisplayTFT colour display Source selection Measurements LC displayOverview of Keypad Commands ButtonInput block Alphanumeric input Operating and Display Elements Fan Ear phones Loudspeakers Battery fuse DC supply ConnectionsFront View Side ViewExternal DC Power Supply RF Input SocketUSB Port SD CardSwitch on Switching OFF Setup Menu Setup Menu SettingsGetting Started Mains and Battery Operation Default Setup Settings AT Time of ShipmentParameter Setting Mains OperationBattery Operation SAT ANALOGUE/DVB-S2 Switch Command Overview of SAT Frequency EntrySAT Analogue Satellite ReceptionFollowing voltages can be called up via button command Command overview for LNB voltageLNB Voltage and 22 KHZ CHANGE-OVER Button LNB voltageSound Carrier Frequency Setting SAT Analogue Level MeasurementLevel overflow and underflow Frequency in MHz Bandwidth Select Sound CarrierDigital SAT Reception Called up via button command Following voltages can be ButtonCommand overview for LNB voltage Setting DVB-S2 Demodulation Parameters Diseqctm Digital Satellite Equipment ControlSAT DVB-S2 Level Measurement Command Overview for Diseqctm Button Hex codeSAT-CTRL menu DiSEqCTM menu Command Overview for Framing Byte Command Overview for Address ByteHex Byte Description Command Overview for Command Byte Hex Command ID DescriptionSwitch Read switching status flag commited port ByteCommand Overview for Data Byte Orbit Polarisation Switch Position Data Byte Low BandList of Single Cable Diseqctm Command Command Overview for Simple DiseqctmSimple DISEQCTM, Tone Burst DVB-S2 MER, BER and Offset Measurement Mpeg Image Representation in DVB-S2Calling up DVB-S2 measurement Press to exit digital receptionCommand overview Locating SatellitesCommand overview for finding Finding Individual Reception FrequenciesAnalogue CABLE/DVB C Switch HF Standard Switch Analogue Cable Demod MenuTV Measurement Analogue TV Cable ReceptionCommand Overview for TV Channel Entry Channel Display and EntryFrequency Display and Entry Command Overview for TV Frequency Entry Cable Analogue Level MeasurementCommand Overview for Measure TV Audio Carrier Frequency Audio Carrier Spacing and LevelLevel Overflow and Underflow StandardSelect Soundcarrier Digital TV Cable Reception Channel Display and Entry Setting DVB-C Demodulation Parameters Level Measurement of DVB-C/DVB-T/H Signals LC display for DVB-C signalsDVB-C/DVB-T/H MER, BER and Offset Measurement To call up DVB-C/DVB-T/H measurementMpeg Image Representation in DVB-C Analogue TERRESTRIAL/DVB T/H Switch HF Standard Switch TerrestrialHF Standard Switch Analogue Terrestrial TV ReceptionChannel Display and Entry Command Overview for TV Frequency Entry Setting DVB-T/H Demodulation Parameters HF Standard Switch DVB-TSelect the required HF bandwidth by using the digit buttons Digital Terrestrial TV ReceptionChannel Display and Entry DVB-C/DVB-T/H MER, BER and Offset Measurement LC display for DVB-T signals Mpeg Image Representation in DVB-TFinding Individual Reception Frequencies Nicam Audio BIT Error Rate Measurement FM Switch Command Overview for FM Frequency EntryFM Measurement Level MeasurementCommand Overview for Find Spectrum Measurement SAT SpectrumTV Spectrum Spectrum Measurement FM Spectrum Storing Device Settings Storing Device SettingsDeleting Device Settings TFT display LC displayStoring Measurement Results Storing Measurement Results in the Device MemorySpectrum Memory Full Only 10 Spec. Possible TFT displayDeleting Measurement Results from the Device Memory Storing Measurement Results on the SD CardStoring Measurement Results Data Logger Entering the Start Line for Automatic MeasuringStarting and Interrupting Automatic Measuring Entering the Stop Line for Automatic MeasuringStoring the Data Logger Measurement Results on the SD Card MessageMaintenance Customer Service Technical Customer SupportFeatures Technical Data RF componentLevel measuring component SIGNAL-TO-NOISE Ratio Technical Appendix+14.1 dB Diseqctm Commands for Kathrein Matrices Command SET for Kathrein MatricesCommand SET for EXR 20 Kathrein Matrix Command SET for EXR 22 Kathrein MatrixChannel Tables Channel UND Frequency TABLE, Standard B/G Frequency in MHZChannel UND Frequency TABLE, Standard L Frequency in MHZ VHF UHFChannel UND Frequency TABLE, D/K Standard Frequency in MHZ VIIChannel UND Frequency TABLE, I Standard Frequency in MHZ Calculation of SAT if Frequency Using the MSK This is done as followsOscillation frequency is made up as follows Hence the values for ARD Das Erste arePage Page 936.3474/A/0409/ZWT Technical data subject to change