Extron electronic AVT 200HD manual Closed Captioning

Page 96

Enabling or disabling audio or video muting, image freeze, closed captioning, and the Program Guide

To enable or disable muting, image freezing, closed captioning, or the Program Guide, click the Off or On button under the name of the function that you want to turn on or off.

Closed Captioning Page

On this page, you can select a closed captioning service and specify the appearance of the closed caption screens on the display. Access the Closed Captioning page by clicking the Closed Captioning link on the sidebar menu of the Control page.

Figure 57. Closed Captioning Page

To select and format the closed captions, make your selections in the following fields:

CC Formatting — Select the Default radio button to format the closed caption using the service default settings. When this button is selected, the drop-down menus in the

Format the Appearance section are grayed out and unavailable.

To format the text and background of the closed caption, select Custom. The menus in the Format the Appearance section become available.

CC Service — Select the radio button for the desired closed captioning service number (1 through 6). To disable closed captioning, select Off.

AVT 200HD Tuner • HTML Configuration and Control

90

Image 96
Contents AVT 200HD Safety Instructions English FCC Class a Notice Conventions Used in this Guide Contents Html Configuration Features About this GuideAbout the AVT 200HD Tuner AVT 200HD Tuner Introduction Application Diagram Application Diagram for the AVT 200HDInstallation Installation OverviewRear Panel Features Video Output ConnectorsComposite and S-video stacked video output connectors Audio Output Connectors Analog audio output connectorsInput Connector Remote Configuration and Control ConnectorsDigital audio output connectors Wiring for RS-232 Control Control ConnectionsEthernet Connection Wiring for IR Control Wiring the IR LinkConnecting to the USB Port Connecting the AVT 200HD to the IR LinkFound New Hardware Wizard Opening Screen AVT 200HD Tuner Installation Front Panel Features AVT 200HD Front PanelHdcp Compliance NBC-4LAPowering On Power-up and Default Cycle Screens ExampleUsing the menus Menus on the LCD ScreenMenu System Overview Menu flow diagram AVT 200HD Menu FlowChannel Setup Menu Selecting the signal sourceScanning for channels Option Scans forScanning Channels with long minor numbers CableOutput Configuration Menu Selecting tune or preset modeSaving presets Not available via the front panel Selecting a channelRecalling presets Selecting the output resolution and refresh rateSelecting the display mode Resolution CompositeSelecting the display aspect ratio Simultaneous Video OutputAudio Configuration Menu Selecting the closed caption serviceComm Setting Menus Comm Setting Menu FlowViewing serial port and IP settings Configuring the serial port and IP parametersUnit Reset Menu Resetting from the Front Panel Unit Reset Menu FlowVolume Control Resetting from the Rear PanelExiting the Menu System Reset Modes Summary Activation Result Purpose/Notes Exec Mode Select Disable Locking and Unlocking the Front Panel Executive ModesUsing the AVT 200HD IR Remote Control Executive Mode Menu FlowInstalling batteries in the AVT 100 Remote Area for Remote Signal ReceptionButtons on the AVT 200HD Remote Control Buttons on the AVT 200 Remote ControlSelecting a Channel or Preset Using the IR Remote Control Channel Selection buttons 0 throughUsing the On-screen Display OSD Locking IR Remote Control AccessIntroductory Display Volume Level Display Channel Information DisplayProgram Guide Serial Port USB PortEthernet Port Ethernet CableConnection Timeouts IP AddressEstablishing an Ethernet Connection Using SIS Commands Tuner-initiated MessagesChip Security for Parental Control Copyright message With an RS-232 connectionTuner Error Responses Error Response ReferencesUsing the Command/Response Tables for SIS Commands Symbol Definitions for AVT 200HD Specific Commands Special CharactersX1@ X1#X2@ X2# X2% X3@ X3#Command/Response Table for AVT 200HD SIS Commands EX!*X@TVSLEX!*X@TVCH X!*X@TVCHX2%TVPR EX2%NG EX2RATEEX2&OPOL EX1TVTM EX1TVOSEX1TVPG X1 Tvcc X1% FsccX1% X1 FsccX1&FSCC X1*FSCCX2*FSCC ExafmtChip Setup Parental Control EX* LangX1$ VolX1$ X3@Chip Setup X3@*X1VCHPX3@*X2@VCHP X2@Other Settings $ TvstTvst ‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘‘ Executive Mode Front Panel Lockout Information RequestsResets EZISymbol Definitions for IP-specific Commands X4#X5# X5$ X6# X6$X7# X7$X8# X8$Command/Response Table for IP-Specific SIS Commands EX4!CPEX!CE EX5@CN ECNEX5#CT ECTEDH EX5$CIECI ECHBmdX9% ,X5$ EX4@ *X10# *X10$ PB BptX4@ *X5EX7$ ,X5$ ID EdiX7$ *X5$ *X4@ X7$ = 0EX4@MH EMHEX4@MD EMDEX7$ ,X7% ,X7 ,X7& E EX7$ ,X7% ,X7 ,X7*X7& E EvtX7$ ,X7% ,X7 ,X7EvtX7$,X7%,X7, string EX7$ ,X7% ,X7 ,X8 FEAccessing the AVT 200HD Configuration & Control Software Downloading and Installing the Software from the WebComputer System Requirements Installing the Software from the Disc Software Button on the DVD Opening ScreenCommunication Setup Window with Telnet Tab Starting the SoftwareRS232 Connection Tab Setup Tab on the Main Window Using the Configuration & Control Program Help File Updating the FirmwareExtron Firmware Loader Window for AVT 200HD Firmware Update in Progress Accessing the Web Pages HtmlExample of a Network Password Dialog Box Special CharactersSystem Status System StatusConfiguration Pages System SettingsIP Settings Fields Unit Name fieldDate/Time Settings Fields Date/Time Settings FieldsTuner Settings Tuner SettingsEdit Channels and Presets section Channel Scan sectionTo hide a channel To show a hidden channelOutput Setup section Executive ModePasswords Setting a passwordRemoving passwords Firmware Upgrade Firmware UpgradeChoose File Window with a Firmware File Selected File Management Uploading FilesAdding a Directory Other File Management ActivitiesControl Pages User ControlSelecting a preset Adjusting the volumeKeypad Closed Captioning Closed CaptioningChip Text Size Text Style Text Fill Text ColorMovie Rating Parental Control section Chip ScreenTV Rating Parental Control section Maximum Allowed TV Rating for Ages sectionChange PIN section Specifications Signal processingRF video input Video output analogVideo output digital SyncAudio output analog Audio output digitalPower VAC to 240 VAC, 50-60 Hz, 25 watts, internal GeneralPart Numbers and Accessories Optional AccessoriesIncluded Parts CablesRack Mounting Procedure Mounting the TunerUL Guidelines for Rack Mounting What is an IP Address? IP AddressingChoosing IP Addresses Class Name Valid Address Range Identifier ArrangementSubnet Mask Pinging for the IP AddressPinging to determine the Extron IP address Class Name Subnet MaskConnecting as a Telnet Client Pinging to determine the web IP addressConnecting to the AVT Open command Telnet tipsSubnetting a Primer GatewaysLocal and remote devices IP addresses and octetsSubnet masks and octets Determining whether devices are on the same subnetUnmasked octets are compared indicated by ? in figure Masked octets are not compared indicated by X in figureFrequency Tables Atsc Frequency TablePhysical Lower Edge Video Audio Upper Edge ChannelAtsc Frequency Table Cable Frequency Table HRC CablePhysical Channel Visual Carrier Frequency MHz Cable Frequency Table Cable Frequency Table USA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe