8.Alignment Procedure
1.DMD Bias Voltage Alignment
Equipment:
-None
Procedure:
1.Watch DMD chip Label
2.Switch the DIP switch on DMD board according to the character on the DMD chip
| B | C | D | E |
1 of SW H1 | 1 | 0 | 1 | 0 |
2 of SW H2 | 1 | 1 | 0 | 0 |
0: Left; 1:Right
2.Color Wheel Delay Alignment Equipment:
-Battery Biased Silicon PIN Detector
-Oscilloscope
-Probe
OSD Default value used for color delay alignment
Item | Value | Item | Value |
|
| Factory>DLP> |
|
Brightness | 0 | Brightness | 0 |
Contrast | 30 | Contrast | 49 |
Color | 60 | CW delay | 20 |
|
|
|
|
Tint | 15 | User>Setup>Whit |
|
Sharpness | 0 | Red Gamma | 66 |
Filter | 2 | Green Gamma | 66 |
Color Temp | 0 | Blue Gamma | 66 |
|
| R gain | 512 |
|
| G gain | 512 |
|
| B gain | 512 |
|
| R Offset | 0 |
|
| G Offset | 0 |
|
| B Offset | 0 |
The default values let optical engine to get maximum contrast and brightness.