3.Definition
3.1 Failure Criteria:
The product is expected to perform to its full potential without loss of function, performance, critical parametric changes, and other undesirable anomalies, over the applied boundaries of this specification. The following product failure are not allowed within the boundaries defined in this specification:
1.Failure including permanent damage, critical parametic changes (optical performance defined in Appendix A), and latent defects.
2.Failure requiring operator intervention.
3.Failure violating external laws, regulatory agency standards, and government directives.
4.Failure resulting in a safety, potential safety, issue.
3.2EUT: Equipment under Test
3.3Q: Peak Acceleration Response divided by acceleration input peak
4.Test Order
Atmospherics, Dynamic, and Safety test sets require separate units and can be processed in parallel. EUT testing shall be performed serially within each set.
Set 1 (3 units) | Set 2 (3 units) | Set 3 |
Dynamics: | Atmospherics: | Safety/EMC: |
Package Drop | Temperature/Humidity, Operating | EFT |
Package Vibration | Temperature/Humidity, | ESD |
|
| |
Shock | Altitude, Operating | |
Bench Drop | Aging | |
|
|
14