A2. BRIGHTNESS UNIFORMITY
Unit: %
Brightness: Default
Contrast: Default
Uniformity = | MIN (E10, E11, E12, E13) | + L2 | + L3 + L4 + L5 + L6 + L7 | + L8 + L9 | |
|
| L1 | |||
|
|
|
| 9 |
|
|
| 1/20w |
E10 | E11 | 1/20h |
L5
E12E13
A3. BRIGHTNESS DIFFERENCE
Unit: %
Brightness: Default
Contrast:Default
Brightness Difference=
(MAX ( E10 , E11, E12 , E13) − MIN ( E10 , E11, E12 , E13))
A4. ANSI CONTRAST
Unit: Contrast : 1
Brightness: Default
Contrast:Default
L1 + L 2 + L3 + L 4 + L5 + L6 + L7 + L8 + L9
9
Contrast Ratio shall be determined from illuminance values obtained from a
Contrast Ratio = Average lux value of the white rectangles/Average lux value of the black rectangles
10