Allstar Products Group HDSWG 1000 owner manual Three Terminal Receivers, Four Wire Receivers

Page 16

C: INSTALLING THE OPERATOR

THREE TERMINAL RECEIVERS

104890

Figure 15: Wiring 3-Wire Receiver

If a three terminal receiver is to be used, the #1 terminal of the receiver is normally COMMON to both the auxiliary transformer (power input) and the radio relay. Most radio manufacturers label this terminal as 24 VAC. Connect a wire from the #1 terminal of the radio receiver to one side of the auxiliary power transformer. Connect another wire from this same terminal of the auxiliary power transformer to the #13 terminal (COMMON) of the HDSWG 1000 terminal strip, as shown in Figure 15. The #2 terminal of the radio receiver is normally the relay contact of the receiver. Connect a wire from this #2 terminal of the radio receiver to the #8 terminal (RADIO OPEN) of the HDSWG 1000 terminal strip. The #3 terminal of the radio receiver is usually labeled RADIO PWR and is connected to the opposite side of the auxiliary power transformer, normally labeled 24 VAC. See Figure 15 for wiring a three wire receiver.

FOUR WIRE RECEIVERS

Four wire receivers replace the "spade" terminals on the RECEIVER

104891

with 4 wires. These wires are typically color coded. The instructions with the receiver must be carefully followed to properly connect the receiver. For any 4 wire receiver, two of the wires will be for power input and two will be for the relay contacts. Connect the two wires for the power input to each side of the 24VAC winding of the AUXILIARY transformer. Connect one of the two wires for the relay to terminal #8 (RADIO OPEN) and the other wire to terminal #13 (COMMON) on the HDSWG 1000 terminal strip. See Figure 16 for connecting 4 wire receivers to the HDSWG 1000.

NOTE: IF THE 4 WIRE RECEIVER INSTRUCTIONS SHOW THAT TWO OF THE WIRES ARE OF THE SAME COLOR AND ARE COMMON CONNECTIONS INSIDE THE RECEIVER, ONE OF THESE WIRES SHOULD BE CONNECTED TO TERMINAL #13 (COMMON) ON THE HDSWG 1000 AND THE OTHER TO ONE SIDE OF THE TRANSFORMER.

WIRING A 3-BUTTON STATION

104892

Figure 17: Wiring 3-Button Station

NOTE: THREE BUTTON STATIONS MAY BE ORDERED WITH THE STOP BUTTON AS NORMALLY OPEN OR NORMALLY CLOSED. THE HDSWG 1000 WILL OPERATE ONLY WITH A NORMALLY OPEN STOP BUTTON. See Figure 17 for instructions on wiring a Three Button Station.

Figure 16: Wiring 4-Wire Receiver

16

Image 16
Contents Hdswg Pre-Setting the Motor Overload Sensitivity PRE-INSTALLATION LOG Date Overload Test Date Tested Dates Operator ServicedGate System Design and Installation Safety Check List Important Installation Notes AS the Installer YOU are Responsible forSwing Gate Entrapment Protection Concrete PADPreparing the Site Placing the Vehicle Detector LoopsElectrical Power Requirements Vehicle Detector Loop Blanking for Swing GatesOther Voltages and Three Phase Systems Service ConduitInstalling Tools RequiredInstalling the Hdswg 1000 ARM Placing the Hdswg 1000 Mechanical UnitInstalling the Hdswg 1000 Control BOX Installing the OperatorElectrical Hook UP Connecting the AC Wiring Connecting the Mechanical Unit to the Control BOXBI-PARTING Wiring Volt InstallationsLeft/Right Hand Installation Limit & Motor Wiring Diagram Bi-Parting Installation Limit & Motor Wiring Diagram Accessory Equipment HOOK-UP Wiring Radio Receivers to the Terminal StripWiring a 3-BUTTON Station Four Wire ReceiversThree Terminal Receivers Wiring a KEYPAD, Card Reader or Telephone Entry System Vehicle Detector PowerWiring Vehicle Detectors Connecting the Vehicle Detector to the Hdswg# Name DescriptionSetting the Limit Switches RIGHT-HANDED Operation Setting the Limit Switches LEFT-HANDED OperationPresetting the Motor Overload Sensitivity Setting the Switch Selectable OptionsApplying Power to the Hdswg Timer to Close SettingPRE-POWER Check List Checking the Indicator LightsPRE POWER-ON Checklist Running the HdswgFinal Setting of the Close Timer Maximum RUN TimerFinal Setting of the Motor Overload Sensitivity Installation Notes for Auxiliary Equipment Vehicle DetectorsGate Opener System Operation & Safety Guide Precautions for Pedestrian Traffic or Residential AreasMaintain the Gate and Gate Hardware a Gate Opener System Operation & SafetyMaintain ALL Components of Gate System Mechanical Unit Exploded View Hdswg 1000 Mechanical Unit Exploded ViewMechanical Unit Parts List ARM KIT & Control BOX Exploded View & PartsTechnical Specifications Physical DriveElectrical Capacities