Allstar Products Group HDSWG 1000 owner manual Applying Power to the Hdswg, Timer to Close Setting

Page 20

D: STARTING THE OPERATOR

TIMER TO CLOSE SETTING

The Timer to Close is controlled by the switch in position #3.

If Switch #3 is set OFF, the Timer to Close function will operate after the gate has opened.

If Switch #3 is set ON, the Timer to Close function will be disabled.

104897

NOTE: SWITCHES 1 AND 2 ARE NOT USED

Figure 20: TIMER TO CLOSE SETTINGS

APPLYING POWER TO THE HDSWG 1000

PRE-POWER CHECK LIST

Before applying power to the HDSWG 1000 for the first time, go through the following check list to ensure that all is in order for the application of power.

1.Check that the HDSWG 1000 power switch is off.

2.Check that the breaker at the power panel is on.

3.With a voltmeter on the proper scale, check that the line voltage at the input to the HDSWG 1000 is the voltage that is expected. Connection of a 115 VAC HDSWG 1000 to an unexpected 230 VAC line is a common occurence. This will cause readily identifiable board failure that WILL NOT BE COVERED UNDER WARRANTY.

4.Manually move the gate to the center of the gate opening.

5.Make sure the Torque Limiter is properly adjusted to slip under a load when a moderate amount of force is applied to the gate in the center of its travel. If the adjustment is too loose, the overload sensitivity will not funtion properly and the Torque Limiter may slip when the gate is under a wind loading. Start by tightening the large nut on the Torque Limiter to 35 ft-lbs/in. To fine tune, increase or decrease this by approximately 5 ft-lbs/in. increments. When a satisfactory setting is found, tighten the set screw in the side of the large nut.

6.Make sure that the proper selection has been made at the Switch selectable options.

7.Make sure that the overload sensitivity is set to its preliminary start up position.

8.Remove the 15 AMP fuse at the Backplane of the HDSWG 1000. (Motor fuse.)

CHECKING THE INDICATOR LIGHTS

There are 14 indicator lights on the Backplane of the HDSWG 1000. See Figure 21. These lights are used to verify proper operation of the HDSWG 1000.

TURN ON THE MAIN POWER SWITCH TO THE HDSWG 1000.

Note that the 24 V lamp is lighted. This indicates that power is applied to the Backplane and boards and the power supply is functioning

Note that no other lamps are lighted.

Connect one end of a short piece of wire (not supplied) to terminal #13 (COMMON).

With the other end of this wire, (make sure that this loose end is free of insulation), touch the following terminals and observe the noted response of the lamps.

1.Terminal #3, Close Lim Sw.: Close Lim Sw light is ON.

2.Terminal #4, Open Lim Sw,: Open Lim Sw light is ON.

3.Terminal #8, Radio Open.: Radio Open light is ON, Open Triac light is ON and Lock light is ON.

4.Remove wire from Terminal #8, Radio Open. Radio Open light goes OUT, Open Triac light stays ON, Lock light stays ON.

5.Terminal #7, Close,: Both Open and Close Triac lights are momentarily ON, then Open Triac Light goes OUT and Close

104898

Figure 21: Indicator Lights

20

Image 20
Contents Hdswg Pre-Setting the Motor Overload Sensitivity PRE-INSTALLATION LOG Date Overload Test Date Tested Dates Operator ServicedGate System Design and Installation Safety Check List Important Installation Notes AS the Installer YOU are Responsible forSwing Gate Entrapment Protection Concrete PADPreparing the Site Placing the Vehicle Detector LoopsElectrical Power Requirements Vehicle Detector Loop Blanking for Swing GatesOther Voltages and Three Phase Systems Service ConduitInstalling Tools RequiredInstalling the Hdswg 1000 ARM Placing the Hdswg 1000 Mechanical UnitElectrical Hook UP Installing the OperatorInstalling the Hdswg 1000 Control BOX Connecting the AC Wiring Connecting the Mechanical Unit to the Control BOXBI-PARTING Wiring Volt InstallationsLeft/Right Hand Installation Limit & Motor Wiring Diagram Bi-Parting Installation Limit & Motor Wiring Diagram Accessory Equipment HOOK-UP Wiring Radio Receivers to the Terminal StripThree Terminal Receivers Four Wire ReceiversWiring a 3-BUTTON Station Wiring a KEYPAD, Card Reader or Telephone Entry System Vehicle Detector PowerWiring Vehicle Detectors Connecting the Vehicle Detector to the Hdswg# Name DescriptionSetting the Limit Switches RIGHT-HANDED Operation Setting the Limit Switches LEFT-HANDED OperationPresetting the Motor Overload Sensitivity Setting the Switch Selectable OptionsApplying Power to the Hdswg Timer to Close SettingPRE-POWER Check List Checking the Indicator LightsPRE POWER-ON Checklist Running the HdswgFinal Setting of the Motor Overload Sensitivity Maximum RUN TimerFinal Setting of the Close Timer Installation Notes for Auxiliary Equipment Vehicle DetectorsGate Opener System Operation & Safety Guide Precautions for Pedestrian Traffic or Residential AreasMaintain ALL Components of Gate System Gate Opener System Operation & SafetyMaintain the Gate and Gate Hardware a Mechanical Unit Exploded View Hdswg 1000 Mechanical Unit Exploded ViewMechanical Unit Parts List ARM KIT & Control BOX Exploded View & PartsTechnical Specifications Physical DriveElectrical Capacities