JAI CV-M300 operation manual Start/Stop Trigger Mode

Page 11

CV-M300

6.3.3. Start/Stop Trigger Mode

The Start /Stop trigger will work in 3 modes:

1.Interlaced with frame accumulation.

2.Interlaced with field accumulation.

3.Non-interlaced with field accumulation.

The exposure time is controlled by the interval between the ext. trigger pulse and the ext. VD signal. The exposure starts at the first HD pulse after the falling edge of the ext. trigger, and stops at the rising edge of the VD pulse. The range can be within 1/77 to 1/10,000 sec.

The Start/Stop mode is a continuous mode where the VD signal must be given continuously. It is not possible to input ext. VD randomly.

For the interlaced modes 2 ext. trigger pulses should be applied for each frame. It is one for each field. In this way it is possible to have different exposure time for the 2 fields within an interlaced frame.

The difference between interlaced frame accumulation or field accumulation can be explained as follow. Both modes have 2 fields output in an interlaced frame. With frame accumulation the contents in the ODD and EVEN sync. fields will come from sensing field 1 and 2 on the CCD sensor. With field accumulation both ODD and EVEN sync. field will contain the signal from sensing field 1 and 2 added together.

Non-interlaced with field accumulation needs only 1 trigger pulse for each field.

To use this mode

Set:

SW1-1, 2 and 3 to ON for 1/10,000 sec.

 

SW1-4 to OFF for normal shutter.

 

SW1-5 to ON for frame accumulation or OFF for field accumulation.

 

SW1-6 to OFF for 2:1 interlaced or ON for non-interlaced.

 

Jumper JP14 on the PK8042board SHORT.

 

Jumper JP7, JP11, JP12 on the PK8041 board SHORT.

 

Jumper JP6, JP8, JP9, JP10 on the PK8041 board OPEN.

Input:

Ext. trigger to pin 5 on 6 pin multi connector. (Cannot be 75 Ohm terminated.)

 

Ext. VD to pin 7 on 12 pin multi connector.

 

Ext. HD to pin 6 on 12 pin multi connector. (If used).

 

HD/VD 75 Ohm termination is done with SW2-1 and SW2-2 on PK8041 board.

Refer to Timing Chart and Cautions on next page.

Detailed switch and jumper setting is described in “7. Mode Setting”.

For connections see “5. Pin Assignment”.

- 10 -

Image 11
Contents CV-M300 Declaration of Conformity Table of Contents General Standard Composition Main FeaturesLocations and Functions Pin Assignment Pin Multi-connector DC-IN/SYNCPin Multi-connector Trigger Functions and Operations Input/Output of HD/VD SignalNormal Shutter Mode External Trigger Mode=4.4∝ S EIA Non-interlaced / Field accumulation modePulse Width Control Mode Ccir Non-interlaced / Field accumulation modePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M300 EIA Ccir Long Time Exposure ModeCV-M300 OFF = On = Mode Setting1. SW1 Switch on the Rear Panel Table for SW 1 SettingSW2 on PK8041 Board Pixel Clock Output Jumper SettingsJP10JP12 Adjustment of Video Signal Output Level Tripod mount plate External AppearanceSpectral Sensitivity SpecificationsAppendix PrecautionsTypical CCD Characteristics Revision Revision E Serial No Users Mode Settings Users ModificationsUser’s Record Camera type CV-M300 Scanning system2700-11088E E1