JAI CV-M300 operation manual SW2 on PK8041 Board

Page 16

CV-M300

Cautions on Shutter.

The image can flicker when the illumination is AC powered.

Highlighted parts of the image will show increasing smear at a shorter shutter time.

7.1.4. Ext. Trigger Shutter Mode

When trigger select SW1-4 is ON. The camera is in ext. trigger shutter mode. The SW1-1, SW1-2 and SW1- 3 are for selecting the shutter speed. The range is from OFF to 1/10,000 second in 8 steps. For each external trigger pulse, the camera will make an exposure with the selected shutter speed.

The shutter time setting is shown in “7.1.3. Table for Shutter Time”.

7.1.5. Trigger Select

SW1-4 is will select the camera operation mode.

OFF is normal mode, where the camera is running continuously.

ON is the ext. trigger shutter mode. Here the external trigger pulse will start the exposure.

7.1.6. CCD Accumulation

SW1-5 will select the CCD accumulation mode.

OFF is field accumulation. It is used for moving objects.

ON is frame accumulation. It is for still objects.

7.1.7. Scanning System

SW1-6 will select the scanning system.

OFF is 2.1 interlaced. It will follow the EIA or CCIR standard for interlaced scanning. ON is non-interlaced.

In EIA the non-interlaced output is continuous ODD field. In CCIR the non-interlaced output is continuous EVEN field.

If the camera is ext. HD/VD synchronized with a non-interlaced sync, SW1-6 be in ON position.

7.1.8. Gamma Correction

SW1-7 will select the gamma correction.

OFF is gamma 1.0. It is linear. Recommended for machine vision and image processing. ON is gamma 0.45. It is non-linear.

7.1.9.Gain Control SW1-8 is for gain select.

OFF is manual gain. Here the gain can be controlled by the GAIN potmeter on the rear panel.

ON is the AGC mode. Here the gain is adjusted automatically. The AGC level can be adjusted by VR3 on PK8042 board. See “8. Adjustment of Video Signal Output Level”.

7.2. SW2 on PK8041 Board

This switch is to select 75 Ohm termination or TTL for ext. HD and ext. VD.

SW2-1 is for HD signal. SW2-2 is for VD signal.

ON is 75 Ohm terminated. (Factory setting). OFF is TTL level.

H D VD

ON

12

O F F

S W 2

- 15 -

Image 16
Contents CV-M300 Declaration of Conformity Table of Contents Standard Composition Main Features GeneralLocations and Functions Pin Multi-connector Trigger Pin Multi-connector DC-IN/SYNCPin Assignment Input/Output of HD/VD Signal Normal Shutter ModeExternal Trigger Mode Functions and OperationsEIA Non-interlaced / Field accumulation mode =4.4∝ SCcir Non-interlaced / Field accumulation mode Pulse Width Control ModePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M300 Long Time Exposure Mode EIA CcirCV-M300 Mode Setting 1. SW1 Switch on the Rear PanelTable for SW 1 Setting OFF = On =SW2 on PK8041 Board Jumper Settings Pixel Clock OutputJP10JP12 Adjustment of Video Signal Output Level External Appearance Tripod mount plateSpecifications Spectral SensitivityTypical CCD Characteristics PrecautionsAppendix Users Mode Settings Users Modifications User’s RecordCamera type CV-M300 Scanning system Revision Revision E Serial No2700-11088E E1