JAI CV-M300 Mode Setting, 1. SW1 Switch on the Rear Panel, OFF = On =, Table for SW 1 Setting

Page 15

CV-M300

7. Mode Setting

Cautions on Mode Setting.

Before making any mode or jumper setting turn the power OFF.

7.1.1. SW1 Switch on the Rear Panel

Factory settings for SW1 are with all 8 switches in OFF position.

OFF = <

ON = >

SW1

OFF ON

1/50

1/125

1/250

1/500

1/1000

1/2000

1/4500

1/10,000

Seconds

 

 

 

1

<

< < < >

>

> >

 

 

 

 

 

SHUTTER

2

<

< > > <

<

> >

 

 

 

 

 

 

3

<

> < > <

>

< >

 

 

 

 

 

TRIGGER

4

 

Normal

<

> External trigger

 

 

 

 

ACCUM

5

 

Field

<

> Frame

 

 

 

 

 

INTERLACE

6

Interlaced

<

> Non-interlaced

 

 

Switchno.

 

GAMMA

7

 

1.0

<

>

0.45

 

 

 

Swichfunction

8

 

Manual <

>

 

Modesetting

 

 

231

 

GAIN

 

Auto

 

 

.ON

ShutterdataMSBtaLSB

 

 

OFF

ReferForshuttertoshutterspeedtableselect7.1.3.

The shutter values are given for a CCIR camera having the factory settings. Shutter values for other

setups and EIA cameras can be seen in table 7.1.3.

 

 

 

 

 

 

 

 

 

7.1.2. Table for SW 1 Setting

 

 

 

 

 

 

 

 

 

 

4

 

Triggerselect

 

 

Normal

 

 

 

Ext.trigger

5

CCDaccumula

 

Fieldaccumulation

 

Frameaccumulation

7

Gammacorrection

 

 

Gamma=1.0

 

 

 

Gamma=0.45

6

Scanningsystem

 

 

2:1interlaced

 

 

 

Non-interlaced

8

SW1-2

Gain

 

 

Manualgain

 

 

 

 

AGCon

SW1MSB-1

SW1LSB-3

 

 

 

Shutterspeed(sec.)

 

 

FF

FFFFN

 

Normalshutter

 

 

2250

Ext.triggershutter

ON

 

1/100Off

 

 

 

EIA:1/601/125(CCIR:1/50)

ON

ON

 

 

 

 

 

1/10,000

 

 

7.1.3. Table for Shutter Time

 

 

 

 

 

 

 

 

 

 

 

 

FF

 

 

 

 

 

 

45

 

 

 

- 14 -

Image 15
Contents CV-M300 Declaration of Conformity Table of Contents General Standard Composition Main FeaturesLocations and Functions Pin Multi-connector DC-IN/SYNC Pin Multi-connector TriggerPin Assignment Functions and Operations Input/Output of HD/VD SignalNormal Shutter Mode External Trigger Mode=4.4∝ S EIA Non-interlaced / Field accumulation modePulse Width Control Mode Ccir Non-interlaced / Field accumulation modePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M300 EIA Ccir Long Time Exposure ModeCV-M300 OFF = On = Mode Setting1. SW1 Switch on the Rear Panel Table for SW 1 SettingSW2 on PK8041 Board Pixel Clock Output Jumper SettingsJP10JP12 Adjustment of Video Signal Output Level Tripod mount plate External AppearanceSpectral Sensitivity SpecificationsPrecautions Typical CCD CharacteristicsAppendix Revision Revision E Serial No Users Mode Settings Users ModificationsUser’s Record Camera type CV-M300 Scanning system2700-11088E E1