Fujitsu RX600 S4 manual Completion, Closing the server

Page 47

10 Completion

VCAUTION!

Make sure you observe the safety notes in the chapter “Safety instruc- tions” on page 11ff.

10.1Closing the server

Figure 29: Mounting the housing cover

ÊPosition the cover on the server in such a way that the rear edge protrudes 1-2 cm from the housing (see circle).

ÊPush the housing cover forward as far as possible.

ÊFasten the housing cover to the front of the system with the two captive screws (see page 18).

ÊInstall the server in the rack.

IThe relevant procedure is described in the operating manual.

ÊFasten the server in the rack cabinet using the knurled screws.

ÊPlug in the power plugs and switch the server on.

RX600 S4

Options Guide

47

Image 47
Contents Primergy RX600 S4 Server Certified documentation according to DIN EN ISO Comments… Suggestions… Corrections…Contents Contents Documentation overview PrefaceConcept and target group of this manual Further sources of information Extensions and conversions Notational conventions Preface ServerView Remote Management Notational conventionsProcedure Page Before starting up Safety instructionsInstallation and operation Safety instructions Working with CDs/DVDs and CD/DVD drives BatteriesLaser information RX600 S4 Opening the server PreparationOpening the server Preparation Removing the housing coverMain memory Page Processors Installing additional processorsRemoving the processor cover Installing additional processorsRemoving the dummy heat sink ProcessorsOpening the socket lever Installing the processorFastening the heat sink Installing the heat sinkMounting the processor cover Mounting the processor coverRemoving the heat sink Replacing a processorReplacing a processor Installing the new processorProcessors Page Removing the module frame Accessible drivesInstalling the CD/DVD drive Mounting a CD/DVD drive Installing the CD/DVD driveMounting the drive in its frame Accessible drivesConnecting a CD/DVD drive Installing a tape drive Module frame with sliding rails Installing a tape driveFastening the sliding rails on the drive Mounting the tape drive Connecting the tape driveCable routing from the tape to the PCI controller Page Controllers in non-hot-plug PCI slots Installing controllersInstalling a controller in a non-hot-plug PCI slot Installing controllersInstalling the battery iBBU Battery for the RAID5 controllerPosition of the SAS riser card in the server Installing the battery iBBUSAS riser card top and battery iBBU bottom Battery for the RAID5 controllerPage Closing the server CompletionPage Abbreviations Abbreviations EMP IBBU LED RoMB PS/2RoHS SBE VRM RAID5 Index