This screen allows you to set the actions the operator can take, what relays will be activated and what cameras are associated with other cameras.
•Action : There are three possible settings. Timed: The alarm will “time out” at the designated time (Hold Time) unless the operator clears it earlier. Latched: The alarm remains active until the operator acknowledges it. Trans (Transparent): The alarms are not latched and cannot be cleared by the operator.
•Relay : There are four possible relay settings. 1 or 2: Sets either
internal relay 1 or 2 to be activated by an alarm. 1&2: Sets both
internal relays 1 and 2 to be activated by an alarm. Off: Neither internal relay will be activated by an alarm.
•Associated : This button allows you to associate other cameras with a camera that is in an alarm condition. Selecting this item will take you to the Associated Camera Setup submenu.
•< Back : This takes you to the Alarm Action Setup (1) submenu.
•Exit : Saves your changes and returns to the Main Menu.