Manual Alarm Action Setup (2) | ENGLISH |
|
<Figure 22 > Manual Alarm Action Setup (2) screen.
This screen allows you to set the actions the operator can take, what relays will be activated and what cameras are associated with other cameras.
•Action : There are three possible settings. Timed: The alarm will “time out” at the designated time (Hold Time) unless the operator clears it earlier.
Latched : The alarm remains active until the operator acknowledges
it. Trans (Transparent): The alarms are not latched and cannot be cleared by the operator.
•Relay : There are four possible relay settings. 1 or 2: Sets either
internal relay 1 or 2 to be activated by an alarm. 1&2: Sets both
internal relays 1 and 2 to be activated by an alarm. Off: Neither internal relay will be activated by an alarm.
•Alarm Link : This selects whether the alarm action will be linked or not. It can be set to Off or any of the 9 alarm actions. All alarm actions take priority over manual alarm actions.