Page 22

User Interface and Navigation

Figure 15

Main Menu

2

3

4

5

1

 

 

 

6

7

1.Display Area

2.BACK

3.FORWARD

4.ENTER–confirms the entry or selection.

5.HOME–changes to the display of measured values. The pop-up toolbar cannot open from the menu window. To view the Main Menu from this display, touch the Home button and then the bottom of the screen.

6.UP–scrolls up

7.DOWN–scrolls down

4.2.1.3 Navigating the Menu Windows

To view a menu item, touch the menu item or use the UP and DOWN keys to highlight the item. The menu item remains highlighted for approximately 4 seconds after it is selected. To view the highlighted command, select the area to the left of the menu item or select the ENTER button.

A “+” next to a menu command indicates there is a submenu. Touch the “+” to view the submenu. An “i” next to a menu command indicates it is information only.

If a menu item is editable, highlight the item and touch the far-left part of the menu item until it is highlighted and press ENTER or double-tap the highlighted item. A keypad will be displayed to change an entry (Figure 17 on page 23) or a list box will be displayed (Figure 18 on page 24).

Messages are displayed in the message window (Figure 19 on page 24).

If an entry is incorrect, repeat the entry with the correct values. If the entry is outside the working range, a correction to the entry is made automatically.

22

Image 22
Contents Digital PC sc and RC sc ¾-inch Combination pH/ORP Sensor Page Table of Contents Table of Contents Combination pH and ORP Sensor Specifications SpecificationsDigital Gateway Specifications Page General Information Safety InformationPrecautionary Labels Use of Hazard InformationGeneral Information General Sensor InformationSensor Body Styles Operating Precaution Digital GatewayPage Section Installation Wiring the sc Sensor to the Digital GatewayInstallation Proper Wire Preparation and InsertionWiring the Digital Gateway Cat. No Hard-wiring the Digital Gateway to the sc100 Wiring the Sensor at Terminal Block J5 Terminal Number Terminal Designation Wire ColorConnecting the Sensor to the sc1000 Connecting the Sensor using the Quick-connect FittingsDigital Gateway Dimensions Mounting the Digital GatewayPage User Interface and Navigation Using the sc100 ControllerController Key Functions/Features Number Key FunctionImportant Key Presses User Interface and Navigation Controller Display FeaturesDisplay Display Features Using the sc1000 ControllerUser Interface and Navigation Navigating the Menu Windows Main MenuKeypad List Box Message windowPH Sensor Setup Menu Sensor SetupSensor Diagnostics Menu for pH and ORP OperationConfigure OperationORP Sensor Setup Menu AC FrequencyOne Point Automatic Calibration PH CalibrationTwo Point Automatic Calibration Operation One Point Manual Calibration Two Point Manual CalibrationConcurrent Calibration of Two Sensors for pH and ORP ORP CalibrationOne-point Manual Calibration Adjusting the Temperature Page Maintenance Maintenance ScheduleCleaning the Sensor MaintenanceTroubleshooting the pH or ORP Sensor TroubleshootingError Codes Error CodesPage Item Description Replacement Parts and AccessoriesReplacement Items, Accessories, and Reagent and Standards Catalog NumberPage A. Customers How to OrderTechnical and Customer Service U.S.A. only Information RequiredRepair Service CanadaLimitations Limited WarrantyLimitation of Remedies Page Immunity Product SafetyCompliance Information EmissionsFCC Part 15, Class a Limits Compliance InformationSensor Modbus Registers Appendix a Modbus Register InformationGroup Name Tag Name Register Data Length Description Type Modbus Register Information PH Measurement Theory Appendix B General pH InformationWhere PID Controller Basics General pH InformationIntegral DerivativePage Index