Hach 6120118 User Interface and Navigation Controller Display Features, Important Key Presses

Page 20

User Interface and Navigation

4.1.1 Controller Display Features

When a sensor is connected and the controller is in measurement mode, the controller automatically identifies the connected sensors and displays associated measurements.

The display will flash on startup, when a sensor error has occurred, and when a sensor is being calibrated.

An active system warning will cause the warning icon (a triangle with an exclamation point inside) to be displayed on the right side of the display. See Figure 13.

Figure 13

Display

1 SENSOR NAME:

2 7.00 pH

3 TEMP: 23.0°C

4

5

6

1.

Status bar. Indicates the sensor name and status of relays. The relay

4.

Parameter

 

letter is displayed when the relay is energized.

 

 

 

 

 

 

2.

Main measurement

5.

Warning icon area

 

 

 

 

3.

Secondary measurement (if applicable)

6.

Measurement units

 

 

 

 

4.1.2Important Key Presses

Press HOME then the RIGHT or LEFT key to display two readings when two sensors are connected. Continue to press the RIGHT or LEFT key to toggle through the available display options as shown below.

Press the UP and DOWN keys to toggle the status bar at the bottom of the measurement display to display the secondary measurement (temperature) and output information.

SENSOR NAME:

pH

7.00 pH

TEMP: 23.0°C

SENSOR NAME:

pH

7.00 pH

OUTPUT1: 12.00 mA

SENSOR NAME:

pH

7.00 pH

OUTPUT2: 12.00 mV

When in Menu mode, an arrow may appear on the right side of the display to indicate that more menus are available. Press the UP or DOWN key (corresponding to the arrow direction) to display additional menus.

MAIN MENU

SENSOR DIAG SENSOR SETUP

SYSTEM SETUP

TEST/MAINT

SYSTEM SETUP

OUTPUT SETUP

RELAY SETUP NETWORK SETUP

DISPLAY SETUP

SYSTEM SETUP

DISPLAY SETUP

SECURITY SETUP LOG SETUP

CALCULATION

SYSTEM SETUP

SECURITY SETUP

LOG SETUP CALCULATION

ERROR HOLD MODE

20

Image 20
Contents Digital PC sc and RC sc ¾-inch Combination pH/ORP Sensor Page Table of Contents Table of Contents Digital Gateway Specifications SpecificationsCombination pH and ORP Sensor Specifications Page Safety Information Precautionary LabelsGeneral Information Use of Hazard InformationSensor Body Styles General Sensor InformationGeneral Information Operating Precaution Digital GatewayPage Section Installation Wiring the sc Sensor to the Digital GatewayInstallation Proper Wire Preparation and InsertionWiring the Digital Gateway Cat. No Hard-wiring the Digital Gateway to the sc100 Wiring the Sensor at Terminal Block J5 Terminal Number Terminal Designation Wire ColorConnecting the Sensor to the sc1000 Connecting the Sensor using the Quick-connect FittingsDigital Gateway Dimensions Mounting the Digital GatewayPage Using the sc100 Controller Controller Key Functions/FeaturesUser Interface and Navigation Number Key FunctionDisplay User Interface and Navigation Controller Display FeaturesImportant Key Presses User Interface and Navigation Using the sc1000 ControllerDisplay Features Navigating the Menu Windows Main MenuKeypad List Box Message windowSensor Setup Sensor Diagnostics Menu for pH and ORPPH Sensor Setup Menu OperationConfigure OperationORP Sensor Setup Menu AC FrequencyTwo Point Automatic Calibration PH CalibrationOne Point Automatic Calibration Operation One Point Manual Calibration Two Point Manual CalibrationOne-point Manual Calibration ORP CalibrationConcurrent Calibration of Two Sensors for pH and ORP Adjusting the Temperature Page Maintenance Maintenance ScheduleCleaning the Sensor MaintenanceTroubleshooting Error CodesTroubleshooting the pH or ORP Sensor Error CodesPage Replacement Parts and Accessories Replacement Items, Accessories, and Reagent and StandardsItem Description Catalog NumberPage How to Order Technical and Customer Service U.S.A. onlyA. Customers Information RequiredRepair Service CanadaLimitation of Remedies Limited WarrantyLimitations Page Product Safety Compliance InformationImmunity EmissionsFCC Part 15, Class a Limits Compliance InformationGroup Name Tag Name Register Data Length Description Type Appendix a Modbus Register InformationSensor Modbus Registers Modbus Register Information Where Appendix B General pH InformationPH Measurement Theory PID Controller Basics General pH InformationIntegral DerivativePage Index