Nikon MRDI user manual Ssm

Page 15

SSM

This command allows you to set the Sync mode. When selecting the option you need, enter the appropriate single digit number, and then hit enter.

Value Function

The camera returns …………..…..1 Free run

2External Sync

3External Sync, fixed integration

4External Sync, electronic shutter

SCM

This command allows you to select a correction mode. When selecting the option you need, enter the appropriate single digit number and then hit enter.

Value Function

The camera returns……………….1 M1 (1st memory)

2M2 (2nd memory)

3Offset Correction

4Gain Correction

5No Correction

6Full Correction

STP

This command allows you to select a test pattern. When selecting the option you need, enter the appropriate single digit number, and then hit enter.

Value Function

No output from camera…………1 Horizontal Ramp

2Vertical Ramp

3Vertical Stripes and Ramp

4Open

54096

60

Other Video

CBR

This command allows you to change the Baud Rate. You will not see anything on your monitor.

Here is a table of stored rates in the camera…Value

Function

1

9600

2

19200

3

38400 (Default)

4

57600

5

115200

If you just can’t resist changing the baud rate, select the appropriate single digit number and hit enter.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev A • 15 of 41

Image 15
Contents OWL Camera Series CAM/CMOS-2K.LS Terminology CAM/CMOS-2K.LS Line Scan Camera Rev a Fairchild Imaging, IncTable of Contents Camera Link Introduction TroubleshootingHandling Instructions Product SupportUsability Camera HighlightsDescription ProgrammabilityFull Spectrum of Applications Camera Specification RDI and Mrdi Performance SpecificationLink Thermal ConsiderationsRDI and Mrdi Responsivity Curve Image Sensor Page Installation Overview Connectors, Pinouts, and CablesCamera Hardware Interface Camera Pin # Frame Grabber Pin # Channel Link Signal Power SupplyLED Indicator Status Lamp Hirose HR25-7TR-4P ReceptacleBack View of CAM/CMOS 2K.LS Commands Camera ControlQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Command Definition Summary Camera Command SummaryGSN Four Modes for Synchronizing with the CAM/CMOS 2K.LSSummary of CAM/CMOS-2K.LS Modes Line Start End 2 -- Mode 1 Freerunning 3 -- Mode 2 ExSync Synchronization Data Camera Output ElectShutter CAM/CMOS-2K.LS Synchronization Timing ValuesMechanical and Optical Guidance Camera Dimensions and Mounting FacilitiesLens Mount Extender Tube LensingPage Page Light Sources LensesPositioning Accuracy of the Sensor Chip in the Camera IlluminationLens Modeling Preventing ESD Damage Cleaning the Sensor WindowHandling Instructions Electrostatic DischargeOther Areas You Should Check TroubleshootingCheck the Obvious Things Out First Use the Camera Control Interface to Perform ChecksHorizontal Lines or Patterns in Output Data Clocking/Output SignalsNo Output Or Non Specification Output Everything Seems To Be Working, But No ImageProduct Support Camera LinkTM Introduction Channel Link is a Widely-Used Signaling MethodVideo Data Signals Camera Control SignalsCommunication Power Port AssignmentsFor More Information on CameraLinkTM Figure A.1 Channel Link Operation Camera Link Connections -- the MDR 26-Pin ConnectorPage Page Figure A.4 Camera Link Cable