Nikon MRDI user manual Camera Specification RDI and Mrdi Performance Specification

Page 6

Full Spectrum of Applications

Precision manufacturing inspection

Web inspection

Sorting and routing

Biomedical readout systems

Diagnostic systems

1.2Camera Specification:

RDI and MRDI Performance Specification

Table 1.2.1

Functions

RDI

 

MRDI

Data rates

Up to 80 MHz

Up to 80 MHz

Line rates

38 KHz

2.9 KHz

 

Dynamic Range

High gain 650:1

High gain 10,000:1

 

Low gain 1100:1

Low gain 31,000:1

Resolution

2048 pixels

2048 pixels

 

Pixel size

7m x 7m

7m x 7m

 

Max Clock speed

80 MHz

80 MHz

 

Max Pixel Clock per Output

40 MHz

40 MHZ

 

Anti Blooming

15000 X

15000 X

 

Digitized (ADC) Output

12 bits

12 bits

 

Pixel gain selectable pixel-by-

1X or 8.5X

1X or 8.5X

 

pixel

 

 

 

Output Gain Range

18 dB

18 dB

 

External Synchronization

Option available

Option available

Random Noise (pk-pk) rms*

44DN pk-pk, 6DN RMS

3DN pk-pk,

0.4DN RMS

Noise Equivalent Exposure

9.7 pJ/CM2 *

.7 pJ/CM2

 

Sat. Equivalent Exposure

5 nJ/CM2 * 40 nJ/CM2**

5 nJ/CM2

40 nJ/CM2**

Intuitive command-control

See Section 3.2

See Section 3.2

instruction set

 

 

 

Sensitivity: High gain

>700 DN/nJ/cm2

>700 DN/nJ/cm2

Low gain

61.5 DN/nJ/cm2

61.5 DN/nJ/cm2

 

 

 

 

Flat field correction

Internal

Internal

 

Lens mount type

M58 to Nikon F-mount &

M58 to Nikon F-mount &

 

C – mount

C-mount

 

Body Size (W H D)

3.92” W x 3.92”H x 1.84 D

3.92” W x 3.92”H x 1.84 D

Power Supply

5.0V

5.0V

 

Power Dissipation

2.5W

2.5W

 

Ambient Operating Temp

0 to 45° C

0 to 45° C

 

Storage Temp

0 to 75° C

0 to 75° C

 

Power Connector

4 – pin Hirose HR10A-7R-4P

4 – pin Hirose HR10A-7R-4P

Data Connector

MDR-26 CameraLinkTM config.

MDR-26 CameraLinkTM config.

 

Single Base

Single Base

 

One 3m 10226-6212VC

One 3m 10226-6212VC

Control connector

CameraLinkTM Connectors

CameraLinkTM Connectors

*At High Gain ** At Low Gain

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev A • 6 of 41

Image 6
Contents OWL Camera Series CAM/CMOS-2K.LS CAM/CMOS-2K.LS Line Scan Camera Rev a Fairchild Imaging, Inc TerminologyTable of Contents Product Support TroubleshootingHandling Instructions Camera Link IntroductionProgrammability Camera HighlightsDescription UsabilityCamera Specification RDI and Mrdi Performance Specification Full Spectrum of ApplicationsThermal Considerations LinkRDI and Mrdi Responsivity Curve Image Sensor Page Installation Overview Connectors, Pinouts, and CablesCamera Hardware Interface Power Supply Camera Pin # Frame Grabber Pin # Channel Link SignalLED Indicator Status Lamp Hirose HR25-7TR-4P ReceptacleBack View of CAM/CMOS 2K.LS Commands Camera ControlQuick Start with the Camera LinkTM Interface You must cover lens when performing this operation SSM LED Camera Command Summary Command Definition SummaryFour Modes for Synchronizing with the CAM/CMOS 2K.LS GSNSummary of CAM/CMOS-2K.LS Modes Line Start End 2 -- Mode 1 Freerunning 3 -- Mode 2 ExSync Synchronization Data Camera Output ElectShutter Synchronization Timing Values CAM/CMOS-2K.LSCamera Dimensions and Mounting Facilities Mechanical and Optical GuidanceLensing Lens Mount Extender TubePage Page Illumination LensesPositioning Accuracy of the Sensor Chip in the Camera Light SourcesLens Modeling Electrostatic Discharge Cleaning the Sensor WindowHandling Instructions Preventing ESD DamageUse the Camera Control Interface to Perform Checks TroubleshootingCheck the Obvious Things Out First Other Areas You Should CheckEverything Seems To Be Working, But No Image Data Clocking/Output SignalsNo Output Or Non Specification Output Horizontal Lines or Patterns in OutputProduct Support Channel Link is a Widely-Used Signaling Method Camera LinkTM IntroductionVideo Data Signals Camera Control SignalsCommunication Power Port AssignmentsFor More Information on CameraLinkTM Camera Link Connections -- the MDR 26-Pin Connector Figure A.1 Channel Link OperationPage Page Figure A.4 Camera Link Cable