VER
This command will show you the current software version in your camera.
The camera returns………………...FPGA REV.2.5 The current value may be different
Micro rev. 0.90 Prod rev. A 1.01
SLR
This command allows you to set line rate, enter value and enter.
The range for line rate should be 204 – 38610.
CPO
This command allows you to Calibrate Pixel Offset. You can observe this command by the blinking green/amber LED. When the LED stops blinking, that means that the calibration of the pixels is completed.
You must cover lens when performing this operation!
CPG
This command allows you to Calibrate Pixel Gain. We strongly recommend that this command be done after each CPO. To perform this operation correctly the camera must look at a uniform illuminated light source. The LED will be a blinking amber/red.
VOM
This command reads the different component voltages located within the camera.
The camera returns…………………INPUT = 6.103
3.9VD = 3.225 3.4VS = 3.448 1.5VD = 1.495 1VAD2 = 0.980 1VAD = 0.980
TSB
This command reads the internal camera temperature.
The camera returns…………………Temp 39.42°C (example)
SIT
This command allows you to set the integration time.
Set line rate first (SLR) before using this command.
Enter value plus enter value in microseconds, Range is 20 – 4900.
Fairchild Imaging •