Nikon MRDI user manual Power Supply, Camera Pin # Frame Grabber Pin # Channel Link Signal

Page 11

Table 2.2.1

Camera Pin #

Frame Grabber Pin #

Channel Link Signal

1

1

Inner shield

14

14

Inner shield

2

25

X0

15

12

X0+

3

24.0

X1-

16

11

X1+

4

23

X2-

17

10

X2+

5

22

Xclk

18

9

Xclk+

6

21

X3

19

8

X3+

7

20

SerTC+

20

7

SerTC-

8

19

SerTFG-

21

6

SerTFG+

9

18

CC1-

22

5

CC1+

10

17

CC2-

23

4

CC2+

11

16

CC3-

24

3

CC3+

12

15

CC4-

25

2

CC4+

13

13

Inner shield

26

26

Inner shield

Notes:

Exterior overshield is connected to the shells of the connectors on both ends.

3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.

Unused pairs should be terminated in 100 ohms at both ends of the cable.

2.3 Power Supply

The camera uses a single voltage input, normally set to 5.0V.

Ripple and noise is required to be < 20 mV RMS.

Power is supplied through a Hirose connector.

When installing the mating connector, be sure to line up the slots. This action will assure that you will not bend any of the pins.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev A • 11 of 41

Image 11
Contents OWL Camera Series CAM/CMOS-2K.LS Terminology CAM/CMOS-2K.LS Line Scan Camera Rev a Fairchild Imaging, IncTable of Contents Camera Link Introduction TroubleshootingHandling Instructions Product SupportUsability Camera HighlightsDescription ProgrammabilityFull Spectrum of Applications Camera Specification RDI and Mrdi Performance SpecificationLink Thermal ConsiderationsRDI and Mrdi Responsivity Curve Image Sensor Page Camera Hardware Interface Installation OverviewConnectors, Pinouts, and Cables Camera Pin # Frame Grabber Pin # Channel Link Signal Power SupplyBack View of CAM/CMOS 2K.LS LED Indicator Status LampHirose HR25-7TR-4P Receptacle Quick Start with the Camera LinkTM Interface CommandsCamera Control You must cover lens when performing this operation SSM LED Command Definition Summary Camera Command SummaryGSN Four Modes for Synchronizing with the CAM/CMOS 2K.LSSummary of CAM/CMOS-2K.LS Modes Line Start End 2 -- Mode 1 Freerunning 3 -- Mode 2 ExSync Synchronization Data Camera Output ElectShutter CAM/CMOS-2K.LS Synchronization Timing ValuesMechanical and Optical Guidance Camera Dimensions and Mounting FacilitiesLens Mount Extender Tube LensingPage Page Light Sources LensesPositioning Accuracy of the Sensor Chip in the Camera IlluminationLens Modeling Preventing ESD Damage Cleaning the Sensor WindowHandling Instructions Electrostatic DischargeOther Areas You Should Check TroubleshootingCheck the Obvious Things Out First Use the Camera Control Interface to Perform ChecksHorizontal Lines or Patterns in Output Data Clocking/Output SignalsNo Output Or Non Specification Output Everything Seems To Be Working, But No ImageProduct Support Camera LinkTM Introduction Channel Link is a Widely-Used Signaling MethodCommunication Video Data SignalsCamera Control Signals For More Information on CameraLinkTM PowerPort Assignments Figure A.1 Channel Link Operation Camera Link Connections -- the MDR 26-Pin ConnectorPage Page Figure A.4 Camera Link Cable