4.2 Lensing

The CAM/CMOS – 2K.LS as shipped from the factory accepts universal manual "F" mount lenses that are available from a number of suppliers. The standard 0.050" Nikon mounting ring is shown in Figure 4.3 below.

Figure 4.3 below shows that the lens extender tube can be detached by unscrewing it so that an optional "C" mount can be installed. If you wish to do this, please contact your Fairchild Imaging Sales representative.

With the lens mount (lens extender tube and its lockring) removed, the front surface of the camera is seen as a square with a large threaded hole in the center. The "z" distance from the surface of the square to the top of the sensor is 13.72mm.

4.3 Lens Mount Extender Tube

Figure 4.3.1

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev A • 26 of 41

Image 26
Contents OWL Camera Series CAM/CMOS-2K.LS CAM/CMOS-2K.LS Line Scan Camera Rev a Fairchild Imaging, Inc TerminologyTable of Contents Product Support TroubleshootingHandling Instructions Camera Link IntroductionProgrammability Camera HighlightsDescription UsabilityCamera Specification RDI and Mrdi Performance Specification Full Spectrum of ApplicationsThermal Considerations LinkRDI and Mrdi Responsivity Curve Image Sensor Page Camera Hardware Interface Installation OverviewConnectors, Pinouts, and Cables Power Supply Camera Pin # Frame Grabber Pin # Channel Link SignalBack View of CAM/CMOS 2K.LS LED Indicator Status LampHirose HR25-7TR-4P Receptacle Quick Start with the Camera LinkTM Interface CommandsCamera Control You must cover lens when performing this operation SSM LED Camera Command Summary Command Definition SummaryFour Modes for Synchronizing with the CAM/CMOS 2K.LS GSNSummary of CAM/CMOS-2K.LS Modes Line Start End 2 -- Mode 1 Freerunning 3 -- Mode 2 ExSync Synchronization Data Camera Output ElectShutter Synchronization Timing Values CAM/CMOS-2K.LSCamera Dimensions and Mounting Facilities Mechanical and Optical GuidanceLensing Lens Mount Extender TubePage Page Illumination LensesPositioning Accuracy of the Sensor Chip in the Camera Light SourcesLens Modeling Electrostatic Discharge Cleaning the Sensor WindowHandling Instructions Preventing ESD DamageUse the Camera Control Interface to Perform Checks TroubleshootingCheck the Obvious Things Out First Other Areas You Should CheckEverything Seems To Be Working, But No Image Data Clocking/Output SignalsNo Output Or Non Specification Output Horizontal Lines or Patterns in OutputProduct Support Channel Link is a Widely-Used Signaling Method Camera LinkTM IntroductionCommunication Video Data SignalsCamera Control Signals For More Information on CameraLinkTM PowerPort Assignments Camera Link Connections -- the MDR 26-Pin Connector Figure A.1 Channel Link OperationPage Page Figure A.4 Camera Link Cable