9. Silent Skip

The Silent Skip automatically pauses recording when there is a period of silence and resumes recording when sound resumes. This feature is often referred to as voice activated recording. Silent Skip looks for sound below a preset level for three seconds time. When that occurs, the PMD620MKII switches to record pause. When a signal above the preset level is input, recording resumes.

1.From Stop, press and hold the DISPLAY button for one second.

2.Press the VOL + or VOL – button to select Preset Menu. Then press the 1/3/ENTER button to accept.

3.Press the VOL + or VOL – button to select Preset 1, 2, 3 or renamed Preset. Then press the 1/3/ENTER button to accept the selected Preset.

4.Press the VOL + or VOL – button to select “Edit” and press the 1/3/ENTER button to accept.

5.Press the VOL + or VOL – button to select the Silent Skip item. Then press the 8 or 9 button to tab through the Silent Skip choices (Off, –60dB, –54dB, –38dB or –20dB).

6.Press the VOL + or VOL – button to select other Menu choices. When changing the Preset is complete, press the DISPLAY button to store the changes, or press the STOP/ CANCEL button to exit Menu mode without storing any changes.

10. Mic Attenuator

The Mic Attenuator let you select the direct use of microphone(s) that differ in sensitivity.

1.From Stop, press and hold the DISPLAY button for one second.

2.Press the VOL + or VOL – button to select Preset Menu. Then press the 1/3/ENTER button to accept.

3.Press the VOL + or VOL – button to select Preset 1, 2, 3 or renamed Preset. Then press the 1/3/ENTER button to accept the selected Preset.

4.Press the VOL + or VOL – button to select “Edit” and press the 1/3/ENTER button to accept.

5.Press the VOL + or VOL – button to select the “Mic Atten.” item. Then press the 8 or 9 button to tab through the “Mic Atten.” choices (0dB, –12dB or –24dB).

6.Press the VOL + or VOL – button to select other Menu choices. When changing the Preset is complete, press the DISPLAY button to store the changes, or press the STOP/ CANCEL button to exit Menu mode without storing any changes.

62

Image 74
Contents Model PMD620MKII User Guide Page Important to Safety Important Safety Instructions Do not place anything inside Handle the power supply cord carefullyDo not open the rear cover Avertissements Avvertenze EENVORMIGHEIDSVERKLARINGNederlands ÜBEREINSTIMMUNGSERKLÄRUNGDeutschÖVERENSSTÄMMELSESINTYGSvenska VORSICHTDeutsch PRECAUTIONFrançaisPRECAUCIÓNEspañol ATTENZIONEItalianoUNE Remarque Concernant LE Recyclage UMA Nota Sobre a Reciclagem Page Table of Contents File List Preset MenuMenu Utility MenuLimited Warranty Package Contents Features IntroductionPage Quick Start Guide REC STOP/CANCEL REC Pause Display VOL Names and Functions FrontButton Left Line OUT jackPower slide switch RightBottom Rear Back AC adapter connection Using batteriesPreparations Before Use Power Keylock Indicator Safety cautions on handling batteriesBattery remaining indicator Installing a memory card Removing a memory cardClock Setting Font Size How to use a tripod Tripod/Belt Clip AdapterPress the REC button to begin recording Connection DiagramBasic Recording Operation Press the REC Pause button to pause recording Rec Channel Setting Input Jack Setting Description Audio Input for RecordingRecording Format Rec Format Sample Rate Channel Bitrates File ExtensionStereo channel Recording Time ChartRecording Time hours minutes Mono channelAt the Manual Level Control Recording Level ControlEncrypted Recording At ALC Automatic Level ControlRetake Recording Retake recording operation during recordingRetake recording operation during playback Press the 8 or 9 button to choose the file Playback ProcedureBasic Playback Operation Access from File List Search Skip Back Passcode InputDuring Stop mode DisplayDuring Record mode Record Time Total Remain Time Record SetupDuring Playback mode File PropertiesMicrophones Advanced FeaturesMic Power Microphone recommendationsManual Track Low Cut FilterSilent Skip Auto TrackCopy Segment Key Lock C d RemoteExtended Remote Jack Plug Type 1/8T-R-R-S Mini PlugComputer compatible USB modeHow to connect via the USB port Diagram of file structure Machine IDMenu Menu StructureItems and functions Protecting the Menu SettingsMenu List Display DescriptionFile List File list FunctionsPlay InformationFile Rename File Delete Press the 1/3/ENTER button to enter the changesUtility Menu Utility FunctionsLoad Settings Return to Stop modeSave Settings Card CheckBreak File format of the 620preset2.txtCard Format Preset Menu Action Menu FunctionsPreset Rename Table of Preset Order Display Settings DefaultInput Rec FormatRec Channel Sample Rate Level Control Level LEDAuto Track Mic Attenuator Mic Power Low CutInput Jack Battery Auto Power Off Encrypt Rec Menu Lock PasscodeSP Mute Machine ID Default Display Menu Functions Display Selection items DefaultDisplay Menu Brightness Font Size LED Time FormDate Form File Sort Default Select Language Troubleshooting Error Message Details of error processsingFactory Default Specifications How You Can Get Service Americas only Limited WarrantyNon-transferable warranty What We Will Pay ForExclusion of Damages Americas only How State Law Relates to the Warranty Americas onlyMarantz Professional Service Number Americas only Marantz Professional products Sales Office SitePage 3520 10189 00AM