Ricoh FV-L200B1 manual 27/32

Page 27

Command No.

Command Descriptions

20H:

[Exposure time (H) of the electronic shutter] Initial Data: SVR[150] = 0, Data Range: 0 to 4095

SVR[70]

Sets the preset shutter speed (or CCD exposure time) for electronic shutter.

21H:

 

 

SVR[158]

The preset shutter speed is defined by the following formula.

 

Exposure time (shutter speed) = SVR[150] x (1H

cycle time) + SHR[150] x (1CLK cycle time)

 

Notes:

 

 

1. The camera works with the shutter off position (maximum frame exposure time) when both SVR and SHR

 

are set at “0”.

 

 

2. The camera works with the minimum shutter speed when this value is set to 0 and the value of SHR is set

 

between 1 and 306.

 

 

3. The value is replaced with 4095 automatically when the value set greater than 4095.

 

 

22H:

[Exposure time (CLK) of the electronic shutter] Initial Data: SHR[150] = 0, Data Range: 0 to 1919

SHR[70]

Sets the preset shutter speed (or CCD exposure time) for electronic shutter.

23H:

 

 

SHR[158]

The previous section, the preset shutter speed is defined by the following formula:

 

Preset shutter speed = SVR[150] x (1H cycle ti

me) + SHR[150] x (1CLK cycle time)

 

Note 1: The camera works with the shutter off position (maximum frame exposure time) when both SVR and SHR

 

are set at “0”.

 

 

Note 2: The camera works with the minimum shutter speed when SVR is set to 0 and this value is set between 1

 

and 306.

 

 

Note 3: The value replaces by 1919 automatically when the value set greater than 1919

 

 

24H:

[Start line of the variable partial scanning] Initial Data: PSR[150] = 0, Data Range: 0 to 1235

PSR[7..0]

This sets the start line number of the variable partial scanning area.

25H:

 

 

PSR[158]

Actual start line of the partial scanning = this value + 1

 

Note 1: The camera works with full scanning mode when the value of (PSR[ ] + PWR[ ]) is greater than 494.

 

Note 2: The value replaces by 1235 automatically when the value set greater than 1235

 

 

26H:

[Effective line numbers in the variable partial scanning] Initial Data: PWR[150] = 494, Data Range: 0 to 1236

PWR[70]

This sets the number of the total effective lines (image height) in the variable partial scanning mode.

27H:

 

 

PWR[158]

Notes:

 

 

1. The value replaces by 1236 automatically when the value set greater than 1236.

 

2. The camera works with full scanning mode when the value of (PSR[ ] + PWR[ ]) is greater than 2058.

 

 

 

FVL200B1

27/32

User’s Guide Rev. 1.01

 

Image 27
Contents FVL200B1 User’s Guide Rev Uxga CCDTable of Contents Camera Link Connector Connector Specifications/ OUT PowerI/O ConnectorHorizontal Timing Normal Mode Setting 10HNormal Full Scanning Setting 10H 1XX00XXX, 11H Vertical TimingPartial Full Scanning Settting 10H 1XX01XXX, 11H Partial Scanning Setting 10H 1XX01XXX, 11H SUB Variable Partial Scanning Setting 10H 1XX01XXX, 11HBinning Mode Setting 10H Binning Partial Full Scanning Setting 10H 1XX10XXX, 11HSetting 10H 1XX11XXX, 11H Vertical Timing Binning Full ScanningBinning 1/4 Partial Scanning Setting 10H 1XX11XXX, 11H Binning 1/2 Partial Scanning Setting 10H 1XX11XXX, 11HData Order on the Camera Link Output 1TAP10bitPixel Transferring Image 1 Taps Transferring Image(1X1Y )Normal Mode Frame ExposureElectric Shutter Pulse Width Trigger Mode(VReset ) Pulse Width Trigger ModeExposure Timing Pulse Width Trigger Mode NonResetEdge Preset Trigger Mode VReset Edge Preset Trigger ModeEdge Preset Trigger Mode NonReset Reset Mode Communication Settings Communication MethodCommunication Format Name Descriptions 【Example Code】Reading the data from the command 00H Eeprom Camera Control Command Camera Command List24/32 Underline settings are the factory default settings Descriptions of the Camera Control Commands26/32 27/32 28/32 29/32 30/32 31/32 32/32