Ricoh FV-L200B1 manual 29/32

Page 29

Command No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Descriptions

 

 

78H:

 

[Test pattern selection] Initial data: TESTP[7..0] = 00H

 

 

TESTP[70]

 

Sets the test pattern output from the camera.

 

 

 

 

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

 

D6

 

D5

 

D4

 

D3

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D5

 

No Function

Always set as “000”

 

 

 

 

D4 to D0

 

Test pattern

00H: Video output

 

 

01H: Gray scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02H: Horizontal ramp wave

03H: Uniform gray level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(100% white)

 

 

 

 

 

 

 

 

 

 

 

 

 

04H: Uniform gray level

05H: Color bar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(variable level)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06H: Vertical ramp wave

Others: Black

 

 

 

 

 

 

 

 

[Image effect selection] Initial data: EFFCT[7..0] = 00H

 

 

79H:

 

Sets the image effect.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFFCT[7..0]

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

D6

 

D5

 

D4

 

D3

 

D2

 

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7:

 

 

Negative / Positive video selection

0: Positive image

1: Negative image

 

 

D6

 

 

No function

 

 

 

 

 

 

 

 

 

 

 

Always set as “0”

 

 

 

 

D5 to D0:

 

Image effect

 

 

 

 

 

 

 

 

 

 

 

00H: No effect (Original) 01H: 11bit gradation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02H: 10bit gradation

03H: 9bit gradation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04H: 8bit gradation

05H: 7bit gradation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06H: 6bit gradation

07H: 5bit gradation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08H: 4bit gradation

09H: 3bit gradation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0AH: 2bit gradation

0BH: 1bit gradation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0C to 3FH: No function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Prohibited settings. Do not set these values)

 

 

 

 

 

 

 

 

 

 

80H:

 

[EEPROM control] Initial data: E2P[70] = 0

 

 

 

 

 

 

 

E2P[70]

 

Sets the image effect.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

D6

 

D5

 

D4

 

D3

D2

 

D1

 

D0

 

 

 

 

 

 

 

D7 to D2:

 

No function

 

 

 

 

 

 

 

 

 

 

 

Always set as “000000”

 

 

D1:

 

 

Register synchronous update with the EEPROM data

0: Prohibited

1: Accept

 

 

D0:

 

 

Write control to the EEPROM

 

 

 

 

 

0: Prohibited

1: Accept

 

 

Note: This bit is cleared to “0” automatically by the internal processes after the execution of the command.

 

 

 

 

 

 

 

 

 

 

 

 

 

94H:

 

[Active time (us) for the strobe signal]

 

 

 

 

 

 

 

 

 

 

STRB[7..0]

 

Initial data: STRB[23..0] =0, data range: 0 to 2,000,000

 

 

95H:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STRB[15..8]

 

Sets active time for the strobe signal .

 

 

 

 

 

 

 

 

 

 

96H:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STRB[23..16]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FVL200B1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29/32

User’s Guide Rev. 1.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 29
Contents FVL200B1 User’s Guide Rev Uxga CCDTable of Contents Camera Link Connector Connector Specifications/ OUT PowerI/O ConnectorHorizontal Timing Normal Mode Setting 10HPartial Full Scanning Settting 10H 1XX01XXX, 11H Normal Full Scanning Setting 10H 1XX00XXX, 11HVertical Timing Partial Scanning Setting 10H 1XX01XXX, 11H SUB Variable Partial Scanning Setting 10H 1XX01XXX, 11HBinning Mode Setting 10H Setting 10H 1XX11XXX, 11H Setting 10H 1XX10XXX, 11HVertical Timing Binning Full Scanning Binning Partial Full ScanningBinning 1/4 Partial Scanning Setting 10H 1XX11XXX, 11H Binning 1/2 Partial Scanning Setting 10H 1XX11XXX, 11HData Order on the Camera Link Output 1TAP10bitPixel Transferring Image 1 Taps Transferring Image(1X1Y )Electric Shutter Normal ModeFrame Exposure Pulse Width Trigger Mode(VReset ) Pulse Width Trigger ModeExposure Timing Pulse Width Trigger Mode NonResetEdge Preset Trigger Mode VReset Edge Preset Trigger ModeEdge Preset Trigger Mode NonReset Reset Mode Communication Format Communication SettingsCommunication Method Name Descriptions 【Example Code】Reading the data from the command 00H Eeprom Camera Control Command Camera Command List24/32 Underline settings are the factory default settings Descriptions of the Camera Control Commands26/32 27/32 28/32 29/32 30/32 31/32 32/32