Ricoh FV-L200B1 manual Normal Mode Setting 10H, Horizontal Timing

Page 5

2Camera Output Timing Charts

2.1

Normal Mode

 

 

(Setting

10H: 1XX0XXXX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal Full Scanning

 

Partial Full Scanning

 

1/2 Partial Scanning

1/4 Partial Scanning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Normal

x1/2

 

x1/4

Normal

 

x1/2

x1/4

 

Normal

x1/2

x1/4

Normal

x1/2

x1/4

(MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rate

15.3

7.6

 

3.8

 

15.4

 

7.7

3.9

 

30.6

15.3

7.7

61.3

30.6

15.3

(Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock Speed: 36.8181

MHz (Normal), 18.40905 MHzx1/2, 9.204525 MHzx1/4

 

 

2.1.1Horizontal Timing

1 CLK = 108.6422 ns at 3.8fps

1 CLK = 54.3211 ns at 7.6fps

1 CLK = 27.1605 ns at 15.3fps

LVAL

 

1920 CLK

 

 

One horizontal (1H)

 

 

 

 

DVAL

300 CLK1620 CLK300 CLK

FVAL

207 CLK

93

CLK

Video out

 

300 CLK

 

 

 

1620 CLK

 

 

 

300 CLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal blanking

Video output

 

 

FVL200B1

5/32

User’s Guide Rev. 1.01

 

Image 5
Contents FVL200B1 User’s Guide Rev Uxga CCD Table of Contents Camera Link Connector Connector Specifications/ OUT PowerI/O ConnectorHorizontal Timing Normal Mode Setting 10HPartial Full Scanning Settting 10H 1XX01XXX, 11H Normal Full Scanning Setting 10H 1XX00XXX, 11HVertical Timing Partial Scanning Setting 10H 1XX01XXX, 11H SUB Variable Partial Scanning Setting 10H 1XX01XXX, 11HBinning Mode Setting 10H Setting 10H 1XX11XXX, 11H Setting 10H 1XX10XXX, 11HVertical Timing Binning Full Scanning Binning Partial Full ScanningBinning 1/4 Partial Scanning Setting 10H 1XX11XXX, 11H Binning 1/2 Partial Scanning Setting 10H 1XX11XXX, 11HData Order on the Camera Link Output 1TAP10bitPixel Transferring Image 1 Taps Transferring Image(1X1Y )Electric Shutter Normal ModeFrame Exposure Pulse Width Trigger Mode(VReset ) Pulse Width Trigger ModeExposure Timing Pulse Width Trigger Mode NonResetEdge Preset Trigger Mode VReset Edge Preset Trigger ModeEdge Preset Trigger Mode NonReset Reset Mode Communication Format Communication SettingsCommunication Method Name Descriptions 【Example Code】Reading the data from the command 00H Eeprom Camera Control Command Camera Command List24/32 Underline settings are the factory default settings Descriptions of the Camera Control Commands26/32 27/32 28/32 29/32 30/32 31/32 32/32