Sanyo VCC-WB2000P instruction manual Recording Alarm Data, Playing Back Alarm Data

Page 41

Alarm Setting

ID3

Recording Alarm Data

The camera’s internal memory can only record a single alarm event (approximately 16 MB). When an alarm signal is input, the internal memory automatically starts recording alarm data, and this recorded data can then be played back. To record new alarm data, you need to delete the old data and clear the internal memory. If an expansion memory card has been inserted, the data recorded in the camera’s internal memory is automatically transferred to the memory card. The purpose of the memory card is to store the data from the camera’s internal memory, and so it cannot be used for direct recording and playback.

To play back the data that is stored on the memory card, the data needs to be transferred from the memory card back into the camera’s internal memory. Refer to “Playing Back Alarm Data” for further details.

Note:

Data that is stored in the camera’s internal memory cannot be overwritten. To record new data, you should use the ALARM DATA LIST screen to clear the existing data in the internal memory (p. 42)

A new alarm cannot be received while alarm data is being transferred to the expansion memory card.

Data is not recorded directly onto the expansion memory card. The data is first recorded into the camera’s internal memory, and it is then transferred automatically to the expansion memory card.

The alarm data that has been transferred to the expansion memory card cannot be played back directly. The data that is stored on the expansion memory card is first loaded into the camera’s internal memory and it is then played back. Refer to “Playing Back Expansion Memory Card Images”. (p. 42)

During alarm recording, the resolution and compression ratio for the images in the live image screen will be momentarily changed to the settings for alarm recording. In addition, the time taken for the images to be changed in this way may be delayed in some cases.

Playing Back Alarm Data

The data that is stored in the camera’s internal memory or on an expansion memory card can be played back.

Note: If an alarm is detected while existing alarm images are being played back, the new alarm data will not be recorded. However, an alarm detection signal will be output from the ALARM OUT terminal, so that the buzzer or other device can still indicate that an alarm has been received.

1 Click the [LIVE VIEW] button in the main menu.

The live image screen will be displayed.

2 Click the ALARM DATA indicator while it is red or green.

The ALARM DATA LIST screen will be displayed.

The first image that was recorded will be displayed in the PREVIEW screen.

The alarm data will be displayed in the [ALARM DATA] list.

3 Click on an alarm filename in the [ALARM DATA] column, and then click the [PLAY] button in the PREVIEW screen.

The BUFFER DATA VIEW screen will be displayed and playback will start.

– 40 –

English

Image 41
Contents Network Camera VCC-WB2000PContents Precautions Accessories FeaturesOperating environment Power indicator Monitor OUT connectorName and Function of Each Part Lens mount capName and Function of Each Part For C mount type Attaching the LensAttach the CS mount-type lens Turn on the camera’s power Flange Back AdjustmentBasic Connections ConnectionsConnections Inserting the wireless LAN cardRemoving the wireless LAN card PPP Dial-up Connections Network Camera Settings Installation of Plug-in Software Network Camera SettingsClick the Finish button Click the Install buttonUninstalling the plug-in software Camera uses cookies Browser SettingsCookie Settings Language selection window Computer and Camera ConnectionsChanging Access Permissions Accessing Without Setting a PasswordClick the Network button Turn the camera off and then back on againClosing the initial window Network Connection SettingsSanyo Network CAMERA, the Unit is Click the Network button in the main menuID1 ID2 ID3 Network SET SettingsHttp Port Number Network SpeedCurrent Channel Wireless LAN SET SettingsEncryption KEY WEP EnciphermentType in the commands to use for controlling the modem PPP SET SettingsCircuit Type AuthenticationBaud Rate Data SizeAUTO/FINE radio buttons Menu Screen and Main MenuMenu Screen and Main Menu Opening and Closing the Initial Screen Viewing Camera ImagesSelect the language and then click the SET button When you have finished, click the network disconnect buttonViewing Camera Images Clock Unset indicator Live View SettingsClick the Live View button in the main menu Lit green NetcamResolution Expansion Live View SettingsSET button Image Mode settingCamera title display Live image screen displayBack button View Frame OperationsClick the View Frame button in the main menu Live Image Camera SettingsCamera Title IrisBright Camera SettingsElectronic Shutter White BalanceClick the SET button Setting the camera titleType in the new camera title e.g. CAM1 External Alarm Sensor Settings Alarm SettingClick the Alarm button in the main menu Change the External Alarm setting to NC or no Alarm Setting Time Motion Detector SET SettingsPicture Quality Expansion memory cards Alarm Data Recording CapacityInserting the memory card Removing the memory cardClick the Alarm Data indicator while it is red or green Recording Alarm DataPlaying Back Alarm Data Buffer Data View screen Playing Back Expansion Memory Card Images Deleting Alarm ImagesMessage the Unit is Loading Click the Delete buttonPre-alarm and Post-alarm Recording Daylight Saving Mode Clock SET SettingsClock SET TimezoneLanguage Selection RS-232C Settings RS-232C SETClick the RS-232C button in the main menu Click the Language button to change the languageClick the Status button in the main menu Status CheckingFirmware Version SUB-MICROCOMPUTER VersionIs the link indicator flashing? TroubleshootingIf the camera cannot be connected If you forget the IP AddressSpecifications 28 mm SpecificationsDimensions Page Printed on recycled paper 1AC6P1P2583 L5AB2/XE 0702KP-CZ