Sony SNC-RZ30N manual Sending Images to FTP Server, FTP client setting

Page 28

Administrating the Camera

Sending Images to FTP Server

— FTP client setting Page

When you click FTP client on the Administrator menu, the FTP client setting page appears.

Use this page to set up for capturing and sending still images to an FTP server. You can capture a still image at the moment when a trigger occurs by an external sensor input, the built-in activity detection function or a manual trigger button, or capture sequenced still images before and after the trigger. The captured still image(s) is sent to the FTP server (FTP client function). You can also send still images periodically.

Activating/Deactivating the FTP Client Function

— FTP client usage setting Page

To activate the FTP client function, select Use FTP client function and click OK. The FTP client setting page appears.

When you do not use the FTP client function, select Do not use FTP client function and click OK.

Note

The frame rate and operability on the main viewer page may decrease while a file is being transmitted by the FTP client function.

Setting the FTP Client Function

— FTP client setting Page

FTP server name

Type the FTP server name to upload still images up to 64 characters, or the IP address of the FTP server.

User name

Type the user name for the FTP server.

Password

Type the password for the FTP server.

Re-type password

To confirm the password, type the same characters as you typed in the Password box.

Remote path

Type the path to the destination up to 64 characters.

Image file name

Type the basic file name you want to assign to the images when sending to the FTP server. You can use up to 6 alphanumeric, - (hyphen) and _ (underscore) for naming.

Suffix

Select the suffix to add to the file name.

None: No suffix is added. The basic file name is assigned to the image to be sent to the FTP server.

Date/Time: The date/time suffix is added to the file name.

The date/time suffix consists of lower two-digits of year (2 digits), month (2 digits), date (2 digits), hour (2 digits), minute (2 digits), second (2 digits) and consecutive number (2 digits), thus 14-digit number is added to the file name.

Sequence number: A consecutive number is added to the basic file name. A number of up to 10 digits between 0000000000 and 4294967295 is added to the file name.

Tip

When the Mode menu is set to Alarm, the type of alarm and the capture timing to the alarm are added to the suffix.

Type of alarm: S1 (Sensor 1), S2 (Sensor 2), S3 (Sensor 3), AD (Activity Detection)

Capture timing: PR (Pre-alarm), JT (Just alarm), PT (Post-alarm)

Sequence No. clear

Click Apply to reset the Sequence number suffix to 0.

Mode

Select the mode of the FTP client function.

Manual: Sends still images to the FTP server manually. After selecting Manual, click OK. The FTP client function mode is set to Manual.

28

Sending Images to FTP Server — FTP client setting Page

Image 28
Contents Network Camera Owners Record For customers in the U.S.A. SNC-RZ30N onlyDeclaration of Conformity Voor de klanten in NederlandPage Table of Contents Others Precautions How to Use This User’s GuideOperating Precautions Logging in as Administrator Logging in to HomepageWelcome Logging in as a UserOther functions on the welcome page for Administrator About ViewersJava applet viewer ActiveX viewerConfiguration of Main Viewer Menu SectionTip Main viewerImage Control Section Trigger control partsFrame rate View sizeOperating the Camera Controlling the Monitor ImagePanning and Tilting Focusing Panning and tilting using the tabletZooming About the zoom rangeMoving the Camera to the Preset Position Controlling the Application ManuallySending a Still Image File to an FTP Server Sending a Still Image via E-mailCapturing a Monitor Image Controlling Alarm OutputTo save the captured image Basic menu Configuration Administrator MenuApplication menu System setting Configuring the SystemSystem setting Section Date time setting Section Reboot Factory defaultSystem PC current date time Manual current date timeCamera setting Setting the CameraUpper Half of Camera setting Lower Half of Camera setting White balance modeZoom mode Focus modeCamera reset Day/Night modeExposure compensation SaturationConfiguring the Network Network Ethernet settingSetting the User User settingAdministrator, User 1 to Secondary DNSSetting the Security Security settingUser access right Default policySetting the Camera Position and Action Preset position settingProgramming the Tour Tour setting Section Tilt speed SequenceSelected tour name Available periodSetting the FTP Client Function FTP client setting FTP client settingSending Images to FTP Server Alarm mode setting Section Periodical sending mode setting SectionOperating the Digest Viewer FTP server setting Downloading Images from the CameraBuilt-in memory Slot adrv/B-slot bdrvSetting the Smtp Function Smtp setting Sending an Image via E- mailAlarm mode setting Section Alarm out 1 or 2 setting Setting the Alarm Out 1 orSetting the Alarm Out 1 Function Alarm out 1 setting Timer mode setting Section Image memory settingRecording Images in Memory Memory OverwritePeriodical recording mode setting Section Alarm buffer setting Setting the Alarm BufferDirectory Structure of Image Memory Serial setting Communicating Data via Serial PortSetting the Schedule Setting the Activity Detection FunctionSchedule setting Activity detection settingPop-up setting Alarm pop-up textShowing the Pop-up Manual pop-up textUsing the Supplied Setup Program Assigning the IP Address Using the Setup ProgramManual setting Setting the Date and TimeChanging the Communication Bandwidth Rebooting the Camera Assigning the IP Address to the Camera Using ARP CommandsUsing the computer’s date and time