AXIS 215 PTZ/AXIS 215
Unit Connectors
This section describes the following:
•The I/O terminal block (for AXIS 215 PTZ only)
•LED indicators
•Power connection
Note: AXIS 215
Audio in | Status/network/power |
|
Audio out | Indicator LEDs | Network connector |
I/O terminal |
| Control button |
| ||
connector |
| |
|
| Power connector |
AXIS 215 PTZ Network Camera
I/O terminal connector (for AXIS 215 PTZ only)
Used in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. It provides the interface to:
•1 transistor output - For connecting external devices such as relays and LEDs. Connected devices can be activated by VAPIX®, output buttons on the Live View page or by an Event Type. The output will show as active (shown under Event Configuration > Port Status) if the alarm device is activated.
Pin 4 | Pin 2 |
Pin 3 | Pin 1 |
•1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).
•Auxiliary power and GND
Function | Pin number | Notes | Specifications |
|
|
|
|
GND | 1 | Ground |
|
|
|
|
|
12V DC | 2 | Can be used to power auxiliary equipment. Note that the AXIS 215 PTZ itself | Max load = 100mA |
Power |
| cannot be powered via the I/O terminal connector. |
|
|
|
|
|
Digital | 3 | Connect to GND to activate, or leave floating (or unconnected) to deactivate. | Must not be exposed to voltages |
Input |
|
| greater than 12V DC |
|
|
|
|
Transistor | 4 | Uses an | Max load = 100mA |
Output |
| GND pin. If used with an external relay, a diode must be connected in paral- | Max voltage = 24V DC |
|
| lel with the load, for protection against voltage transients. | (to the transistor) |
|
|
|
|
Network connector -
35