Axis Communications 215 PTZ-E Unit Connectors, Terminal connector for Axis 215 PTZ only, Function

Page 35

AXIS 215 PTZ/AXIS 215 PTZ-E - Unit Connectors

Unit Connectors

This section describes the following:

The I/O terminal block (for AXIS 215 PTZ only)

LED indicators

Power connection

Note: AXIS 215 PTZ-E does not support audio and does not have I/O ports.

Audio in

Status/network/power

 

Audio out

Indicator LEDs

Network connector

I/O terminal

 

Control button

 

connector

 

 

 

Power connector

AXIS 215 PTZ Network Camera

I/O terminal connector (for AXIS 215 PTZ only)

Used in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. It provides the interface to:

1 transistor output - For connecting external devices such as relays and LEDs. Connected devices can be activated by VAPIX®, output buttons on the Live View page or by an Event Type. The output will show as active (shown under Event Configuration > Port Status) if the alarm device is activated.

Pin 4

Pin 2

Pin 3

Pin 1

1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).

Auxiliary power and GND

Function

Pin number

Notes

Specifications

 

 

 

 

GND

1

Ground

 

 

 

 

 

12V DC

2

Can be used to power auxiliary equipment. Note that the AXIS 215 PTZ itself

Max load = 100mA

Power

 

cannot be powered via the I/O terminal connector.

 

 

 

 

 

Digital

3

Connect to GND to activate, or leave floating (or unconnected) to deactivate.

Must not be exposed to voltages

Input

 

 

greater than 12V DC

 

 

 

 

Transistor

4

Uses an open-collector NPN transistor with the emitter connected to the

Max load = 100mA

Output

 

GND pin. If used with an external relay, a diode must be connected in paral-

Max voltage = 24V DC

 

 

lel with the load, for protection against voltage transients.

(to the transistor)

 

 

 

 

Network connector - RJ-45 Ethernet connector. Using shielded cables is recommended.

35

Image 35
Contents Axis 215 PTZ/ Axis 215 PTZ-E Legal Considerations About This DocumentAxis 215 PTZ/AXIS 215 PTZ-E Table of Contents Accessing the camera from the Internet Accessing the cameraAccessing from a browser Setting the PasswordPan/Tilt/Zoom controls Live ViewArea Zoom Viewer controls Control panelStill Image Server push not available for Microsoft Internet ExplorerQuickTime Java appletMotion Jpeg Video and Audio StreamsVideo Stream Types Axis Media Control How to stream MPEG-4MPEG-4 protocols and communication methods Audio transmission methods Axis 215 PTZ only Other methods of accessing the video streamAccessing the Audio Streams Axis 215 PTZ only Other MPEG-4 clientsAccessing the setup tools from a browser SetupVideo Stream Video & Image settingsOverlay Settings Overlay image requirements Overlay Image SettingsAdvanced settings Profile@Level Properties MPEG-4 SettingsBit Rate Control Audio Input Audio Settings Axis 215 PTZ onlyEnable Audio Audio ChannelsAudio Output If Microphone is selected set the Input sensitivity toAdvanced Audio Settings Axis 215 PTZ only Modify the Axis Look Live View Config Live View LayoutCustom Settings Upload Own Web Files User Defined Links Show Setup linkDefault Viewer Own HomeExternal Video Viewer settingsHtml Examples Advanced Limits PTZ Configuration Preset PositionsSequence Mode Osdi ZonesControl Queue Advanced Ctrl PanelAdvanced Calibration Event Servers Event ConfigurationClick Add triggered on the Event types How to set up a triggered eventEvent Types Triggered EventScheduled Event How to set up a scheduled eventMotion Detection Pre-trigger and Post-trigger buffersHistory Sensitivity How to configure Motion DetectionPort Status Axis 215 PTZ only ParameterSecurity System Options802.1X Network Admission Control Network Basic TCP/IP SettingsServices Date & TimeLink-Local IPv4 Address Advanced TCP/IP SettingsNetwork Traffic Network QoS Quality of ServiceNetwork Socks Network Smtp email Network Bonjour Network Snmp Network UPnP Network RTP/MPEG-4Upgrade Server See Updating the Firmware, on MaintenanceAdvanced Resetting to Factory Default SettingsConfiguration SupportAxis 215 PTZ Network Camera Unit ConnectorsTerminal connector for Axis 215 PTZ only SpecificationsColor Indication Connection diagramPower connection Updating the Firmware TroubleshootingChecking the Firmware Customer Services Problems with the MPEG-4 format Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Disconnect power from the Axis 215 PTZ/AXIS 215 PTZ-ESnapshot images Video Image ProblemsMechanical problems Lens Technical SpecificationsProcessors and memory Installation, managementAudio Axis 215 PTZ only Software not incl Accessories Optimizing your system File sizesGeneral performance considerations Bandwidth Frame rates Motion JpegFrame rates MPEG-4 Axis 215 PTZ/AXIS 215 PTZ-E Technical Specifications Etrax Ethernet Token Ring Axis Axis own microprocessor Glossary of TermsSee also IP Internet Protocol VOP See VOP URL Uniform Resource Locator An address on the network SSL/TSL Secure Socket Layer/Transport Layer SecurityAxis 215 PTZ/ Axis 215 PTZ-E Glossary of Terms Axis Vapix API IndexAxis 215 PTZ/AXIS 215 PTZ-E Index