3.While this self-check routine is checking the camera's status, focus and frame the subject.

For detailed information on how to properly focus and frame the subject, refer to the Macro 5 SLR User's Guide.

4.Once the camera is properly focused and the status lights are green, press the shutter button (S1/S2) all the way in to take the picture. This action closes the S2 switch.

Closing the S2 switch:

Fires the strobes.

Actuates the shutter.

Note: The camera will take a picture only when it is properly focused, the strobes are fully charged, and the self-check routine is in progress.

5.The picture will automatically eject from the camera when the shutter button is released.

Note: The camera powers down (shuts off) when:

Picture count reaches zero (0).

Self-check continuous loop times out - no camera activity for thirty (30) seconds (button pressed, setting changed, picture taken, etc.).

25

Image 25
Contents Repair Manual Technical Services Burlington Road Bedford MA TEL FAXRev replaces September Contents Purpose of this Manual Organization of this Manual Other Documents Required for ServiceParts Replacement AdjustmentsCamera Description Theory of OperationS1/S2 PC Board SchematicsCamera Description Important Safety Instructions Macro 5 SLR Camera GeneralCamera FeaturesMacro 5 SLR Features Two Built-In Macro 5 SLR Camera Features Cont’dElectronic Flash Units Dual-Light RangefinderRight/Left Hand Grips Battery CompartmentRed Shutter S1 Button Control Panel Control PanelPower Button Control Panel FeaturesLow Battery Reset ButtonLighten/Darken Controls Control Panel Features Cont’dMagnification Status Lights RS232 ReceptacleDate/Time Display Specifications Weight Specifications Cont’d MagnificationDimensions AccessoriesTheory of Operation Operation Camera SetupFilter Kit Macro 5 SLR Camera Camera Setup Picture Taking Macro 5 SLR Camera Picture Taking Adjustments Camera Test Fixture Ranging Aim Lights AdjustmentRange Light Adjustment Range Light Adjustments Grid Position Grid AdjustmentGrid Adjustments Troubleshooting Diagnostics Module Parts Replacement Macro 5 SLR Camera Required Tools and Equipment Disassembly/Assembly of Camera Inspection and CleaningElectrostatic Discharge Warning Removal -1, 5-2 and 5-2a Left/Right Cover Includes Front CoverCamera Disassembly Left/Right Bottom Screw Location Reassembly Removal Figure Front CoverReassembly Removal Figures 5-2 Rear CoverReassembly Bottom cover Bottom CoverReassembly Strobe PC Board Strobe PC BoardReassembly Trigger PC Boards Trigger PC Boards S1/S2 PC Board S1/S2 PC BoardReassembly Control Panel Reassembly Logic PC Board 10 Logic PC Board Camera Back 11 Camera Back Macro 5 SLR Camera Removal -12 and 5-12a Encoder Plate and PC Board12a Encoder PC Board Reassembly 13 Turret Assembly Turret AssemblyReassembly 14 Shutter Solenoid Assembly Shutter Solenoid AssemblyReassembly 15 Aim Light Cable Assembly Bulb Aim Light Bracket AssemblyReassembly 16 Date Code Module Date Code ModuleReassembly Firmware Logic PC Board 17 Firmware CPU Schematics S1/S2 PC Board Encoder PC Board Trigger PC Board Strobe PC Board 1 Strobe PC Board 2 Logic PC Board 1 Logic PC Board 2 Communication PC Board