Polaroid 111523 manual Range Light Adjustment

Page 29

Repair Manual

Macro 5 SLR Camera

 

 

Figure 3-2 Range Light Adjustment

5.Adjust range lights as follows:

Remove the front cover as explained in section 4 of this service manual.

Determine which range light is out of adjustment.

Loosen the applicable adjustment screw (Figure 3-3) and then manually adjust the range light until it merges with the other range light.

Note: If either range light filament is not horizontal (Figure 3-2), loosen the applicable range light clamp screw and then manually rotate the lamp until its filament is correctly positioned.

6.Once both range lights are merged together and properly centered in the test target, tighten the range light adjustment screws being careful not to disturb the adjustment.

7.Recheck the position of the range lights by lightly pressing the red shutter button. The range lights should be merged together and centered in the test target. If necessary, repeat steps 5 through 7 until the range lights are properly merged and centered.

29

Image 29
Contents Rev replaces September Technical Services Burlington Road Bedford MA TEL FAXRepair Manual Contents Purpose of this Manual Organization of this Manual Other Documents Required for ServiceParts Replacement AdjustmentsCamera Description Theory of OperationS1/S2 PC Board SchematicsCamera Description Important Safety Instructions Macro 5 SLR Camera GeneralCamera FeaturesMacro 5 SLR Features Two Built-In Macro 5 SLR Camera Features Cont’dElectronic Flash Units Dual-Light RangefinderRight/Left Hand Grips Battery CompartmentRed Shutter S1 Button Control Panel Control PanelPower Button Control Panel FeaturesLow Battery Reset ButtonLighten/Darken Controls Control Panel Features Cont’dMagnification Status Lights RS232 ReceptacleDate/Time Display Specifications Weight Specifications Cont’d MagnificationDimensions AccessoriesTheory of Operation Filter Kit Camera SetupOperation Macro 5 SLR Camera Camera Setup Picture Taking Macro 5 SLR Camera Picture Taking Adjustments Camera Test Fixture Ranging Aim Lights AdjustmentRange Light Adjustment Range Light Adjustments Grid Position Grid AdjustmentGrid Adjustments Troubleshooting Diagnostics Module Parts Replacement Macro 5 SLR Camera Required Tools and Equipment Electrostatic Discharge Warning Inspection and CleaningDisassembly/Assembly of Camera Removal -1, 5-2 and 5-2a Left/Right Cover Includes Front CoverCamera Disassembly Left/Right Bottom Screw Location Reassembly Removal Figure Front CoverReassembly Removal Figures 5-2 Rear CoverReassembly Bottom cover Bottom CoverReassembly Strobe PC Board Strobe PC BoardReassembly Trigger PC Boards Trigger PC Boards S1/S2 PC Board S1/S2 PC BoardReassembly Control Panel Reassembly Logic PC Board 10 Logic PC Board Camera Back 11 Camera Back Macro 5 SLR Camera Removal -12 and 5-12a Encoder Plate and PC Board12a Encoder PC Board Reassembly 13 Turret Assembly Turret AssemblyReassembly 14 Shutter Solenoid Assembly Shutter Solenoid AssemblyReassembly 15 Aim Light Cable Assembly Bulb Aim Light Bracket AssemblyReassembly 16 Date Code Module Date Code ModuleReassembly Firmware Logic PC Board 17 Firmware CPU Schematics S1/S2 PC Board Encoder PC Board Trigger PC Board Strobe PC Board 1 Strobe PC Board 2 Logic PC Board 1 Logic PC Board 2 Communication PC Board