Repair Manual | Macro 5 SLR Camera |
|
|
Camera Back
Caution: Shock Hazard - High Voltage
Note: Use a dump stick to fully discharge the strobe capacitors before attempting to remove or replace the camera back.
1.Removal (Figure 5-11)
a.Remove the left/right cover assembly as explained on page 39.
b.Remove the rear cover assembly as explained on page 45.
c.Remove the bottom cover as explained on page 47.
d.If applicable, remove the strobe, control, or logic PC boards.
Note: Usually it is not necessary to remove the strobe and logic PC boards and control panel when removing the camera back - just let them dangle by their electrical cables. However, if these components need to be removed during the removal of the camera back, refer to the applicable disassembly procedures in this section of the manual.
e.Disconnect the following electrical cables from the logic PC board:
•J15 (Piezo)
•J16 (Date Code Module)
•J23 (Film Door Switch)
•J25 (Camera Back Flex)
f.Using a torx driver, remove the six (6) screws securing the camera back to the cone assembly.
g.Lift off the camera back.
Note: Be careful not to loose the plastic support plate (provides the necessary screw holes that secure the left side of the cone to the gear side of the camera back).
59