Shure DP11EQ manual Delay

Page 28

Weight

930 g (2.05 lbs)

DYNAMICS PROCESSOR

Gate and Expander

Threshold: ±72 to ±1 dB, 0.5 dB resolution

Attack: 1.0 to 200 ms

Decay: 0.05 to 1 second

Gate Hold Time: 0 to 0.5 seconds

AGC Leveler

Threshold: ±72 to ±1 dB, 0.5 dB resolution

Attack: 0.2 to 3 seconds

Decay: 0.5 to 5 seconds

Hinge: Threshold to ±1 dB, 0.5 dB resolution

Compressor and Limiter

Threshold: ±72 to ±1 dB, 0.5 dB resolution

Attack: 1.0 to 200 ms

Decay: 0.05 to 1 second

Knee: Hard or Soft selectable

No Overshoot Peak Limiter

Propagation delay: 1 ms

Threshold: ±72 to ±1 dB, 0.5 dB resolution

Attack: 0 ms

Decay: 100 ms

PARAMETRIC EQUALIZER

Parametric Filter Frequency Bands

Up to 9 bands, variable frequency, variable Q

Boost/Cut Range

+6 dB to ±18 dB per band

Q Range

1/40-octave to 2 octave

High and Low Shelf/Cut Filters Shelf, +6 to ±18 dB per filter Cut, ±12 dB per octave nominal

DELAY

Up to 1.3 seconds, 21 microsecond resolution

FURNISHED ACCESSORIES

Power Cable (DP11EQ ) . . . . . . . . . . . . . . . . 95A8389

Power Cable (DP11EQE) . . . . . . . . . . . . . . . . 95A8247

5-pin DIN Shure Link Cable . . . . . . . . . . . . . . 95A8676

Single Mount Rack Bracket . . . . . . . . . . . . . . 53A8484

Dual Mount Rack Bracket . . . . . . . . . . . . . . . 53B8484

Straddle Bars . . . . . . . . . . . . . . . . . . . . . . . . . . 53A8443

SERVICE STATEMENT

For additional service or parts information, please

contact Shure's Service department at 1-800-516-2525. Outside the United States, please contact your authorized Shure Service Center.

CERTIFICATIONS

DP11EQ : UL LISTED and cUL LISTED to UL 813 and CSA C22.2 No. 1. Authorized under Verification provision of FCC Part 15 as a Class B Digital Device. DP11EQ E: Conforms to European Union Directives, eligible to bear CE marking. Meets European Union Low Voltage Requirements: VDE GS-Certified to EN 60 950. Meets European Union EMC Emissions Requirements: EN 50 081-1 (1992) [EN 55022]. Meets European Union EMC Immunity Requirements EN 50 082±1 (1992).

INFORMATION TO USER

Changes or modifications not expressly approved by Shure Incorporated could void your authority to

operate this equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

SReorient or relocate the receiving antenna.

SIncrease the separation between the equipment and receiver.

SConnect the equipment into an outlet on a circuit different from that to which the receiver is connected.

SConsult the dealer or an experienced radio/TV technician for help.

English ±27

Image 28
Contents DP11EQ Table of Contents Software Features Hardware FeaturesIntroduction DP11EQ Hardware OverviewFront Panel BackDIP Switches Shure Link Device IDMain Amplifier Audio ConnectionsSubgroup Insert Input Insert Connecting the DP11EQ to a Computer via the RS-232 COM Port Software InstallationDP11EQ Software IntroductionAccessing the Connected DP11EQs Configuring the Computer Serial PortShure Program Group Overview Main Controls Processor Select ButtonsDynamics Processor Dynamics Parameters Gate Dynamics ProcessesExpander AGC Leveler Compressor LimiterSnapshots Editing Dynamics ProcessesParametric Equalizer Parametric Equalizer Edit Boxes and Controls Setting and Adjusting Parametric FiltersHigh- and Low-Frequency Shelf/Cut Filters Response Graph Cutting, Copying, and Pasting Parametric FiltersIN/OUT Meters and Output Control Meter CalibrationDelay for Solving Remote Speaker Alignment DelayDelay for Solving Phase Cancellation Problems Setting Delay by Time Reversing the Output Signal PolaritySetting Delay by Distance Shure Link Networks Shure Link ConnectionsShure Link Options Shure Link Device Menu Maintenance ScenesSettings To Save Settings to DiskTo Recall Settings from Disk Customizing Graph ColorsAppendix A. Specifications Printing DP11EQ SettingsLocking Out the Front Panel Exiting the DP11EQ ApplicationDelay Appendix B. Rack Mounting the DP11EQ Single UnitDual-Mounted Units Mounting in an Equipment RackAudio Connectors Appendix C. Connectors and CablesAudio Cables In. to 1/4 -in. Balanced In. to 1/4 -in. UnbalancedIn. Balanced to 1/4 -in. Unbalanced XLR male to 1/4 -in. BalancedXLR female to 1/4 -in. Unbalanced XLR female to 1/4 -in. BalancedRCA to 1/4 -in. Unbalanced Digital Connectors and Cables Computer Interface Ð 9-Pin to 9-Pin RS-232 CableComputer Interface Ð 9-Pin to 25-Pin RS-232 Cable Shure Link Cable Ð 5-Pin DIN Cable MIDI-compatible cableAppendix D. Keyboard Controls General ControlsIN/OUT Meters and Output Slider Controls Parametric Equalizer Controls