Printing DP11EQ Settings
If you are documenting a sound system, the DP11EQ software offers the option of printing out a hardcopy report showing the settings of a selected unit. To print out a hardcopy of this report:
1.Click on File in the main menu bar of the Main Control Panel.
2.Click on Print...
3.Select any of the desired print options available.
4.Click on the button of the Name: field to display a
5.Click on the OK button.
Locking Out the Front Panel
The front panel of the hardware can be locked via software so that no one may tamper with the unit once installed. To lock the front panel:
1.Click on Options in the main menu bar of the Main Control Panel.
2.Click on Lock Front Panel.
Exiting the DP11EQ Application
1.Click on File in the main menu bar of the Main Control Panel.
2.Select the Exit option of the
APPENDIX A. SPECIFICATIONS
GENERAL
Frequency Response
20 to 20k Hz ± 1.0 dB re 1 kHz
Dynamic Range
104 dB minimum,
Sampling Rate
48 kHz
20 bit resolution
Voltage Gain
±1 dB ± 1dB (power off)
12 dB ± 2 dB (input ±10 dBV, output +4 dBu) ±12 dB ± 2 dB (input +4 dBu, output ±10 dBv)
0 dB ± 2 dB (equal input and output sensitivities)
Impedance
Input: 47 kΩ ± 20% actual
Output: 120 Ω ± 20% actual
Input Clipping Level
+18 dBu minimum (at +4 dBu setting)
+6 dBV minimum (at ±10 dBV setting)
Output Clipping Level
+18 dBu minimum (at +4 dBu setting)
+6 dBV minimum (at ±10 dBV setting)
Total Harmonic Distortion
< 0.05% at 1 kHz, +4 dBu, 20 to 20 kHz
LED Signal Indicators
Signal: ±40 dB
Clip: 6 dB down from input clipping
Propagation Delay from Input to Ouput
0.8ms (all filters flat, no dynamics processing, 0 ms delay), up to 2.1 ms (all processing enabled)
Polarity
Input to output: inverting optional (default:
XLR: pin 2 positive with respect to pin 3
Operating Voltage
DP11EQ: 120 Vac, 50/60 Hz, 50 mA max
DP11EQE: 230 Vac, 50/60 Hz, 25 mA max
DP11EQJ: 100 Vac, 50/60 Hz, 50 mA max
Temperature Range
Operating: 0_ to 60_ C (32_ to 140_ F)
Fuse
DP11EQ: 120 Vac. Fuse: 100 mA, 250V time delay
DP11EQE: 230 Vac. Fuse: 50 mA, 250 V time delay
DP11EQJ: 100 Vac. Fuse: 100 mA, 250 V time delay In order to change a blown fuse, remove the power cord and pry open the drawer with a flathead screwdriver.
FUSE
Dimensions
219 mm x 137 mm x 44 mm 8 5/8 in x 5 3/8 in x 1 3/4 in