Cannon QL Exposure Setting 1 -ShutterSpeed Priority Method, CdS Actuating Lever, How to Measure the Average Brightness

Page 10

            (1000) (1250) (2000)

 

        800. · 1600.

 

          30. · 33.

 

             (31) (32)     (34) 

Figures in parentheses represent intermediate film speeds. 

è

  The film speeds are shown either on the film box cover or on the explanatory sheet. 

CdS Actuating Lever 

The exposure meter can be set into measuring condition by turning the CdS actuating lever towards the lens. 

The CdS actuating lever can be fixed by turning it towards the lens after setting the lock lever at " L" position. If the lock lever is 

returned to its original position ( ~ index) the CdS actuating lever will also return to its original position.

 

è

  The shutter cannot be released while the CdS actuating lever is being turned or when it is locked with the lock lever. 

How to Measure the Average Brightness

 

The exposure meter on the Canon PELLIX QL is of the spot reading type which accurately measures any special spot of the subject. 

Therefore, when measuring a subject with greatly differing dark and bright parts, take two measurements, one each of the dark and 

bright parts. Then obtain the average value and set the F stop or shutter speed accordingly. 

Exposure Setting 1 -Shutter Speed Priority Method 

1.  Set the shutter at a desired speed.

 

2.  Face the camera towards the photographic subject, look into the viewfinder, and press the CdS actuating lever fully.

 

3.  Either keep pressing the lever or lock , the lever and turn the aperture ring.

 

4.  Set the meter needle at the o index within the viewfinder for correct exposure. 

Image 10
Contents Camera Manual Before UsingCanon Pellix To main Chinon/Ricoh manual siteTable of contents Technical Data Technical Data — page 4 Battery Check Mercury Battery Loading :Attaching the Cable Release Safety Device for ShutterFilm Counter Film Winding :Shutter Speed Dial Shutter and Aperture Adjustment :Lens Aperture Lens with A-M Ring Pre-Set Aperture and Checking of Depth-of-FieldRelation Between the Pellicle Mirror, CdS, Diaphragm and Shutter Lens with Manual Aperture RingHow to Use Built-in Exposure Meter : Film Speed SettingHow to Measure the Average Brightness Exposure Setting 1--Shutter Speed Priority Method :CdS Actuating Lever Exposure Setting 2--F Stop Priority Method : Focusing : Holding the Camera : Composition and ViewfinderHolding the Camera : — page 14 Film Loading : Checking Correct Film Loading Setting the Film SpeedFilm Rewinding : Eyepiece Shutter Photography Using Self-timer and Eyepiece Shutter :Flash Synchronization : Distance Scale Uses of Lenses :Changing Lenses Infrared Index " R "Lens Mount (FL and R Series Lenses) Depth of field ScaleFilm Plane Mark Filters : Double Exposure :Proper Care of the Canon PELLIX QL : Cleaning of the CameraCleaning the Lens Storage of CameraCanon Zoom Lenses Interchangeable Lenses and Accessories :Canon Interchangeable Lenses New "Compact Series" LensesTechnical Data AccessoriesCanon Booster Technical Data — page 24